Your browser doesn't support javascript.
loading
Test-Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry.
Andrades-Ramírez, Oscar; Ulloa-Díaz, David; Alfaro Castillo, Bryan; Arroyo-Jofré, Patricio; Castillo-Paredes, Antonio; Chirosa-Ríos, Luis.
Afiliación
  • Andrades-Ramírez O; Facultad de Salud y Ciencias Sociales, Escuela de Ciencias de la Actividad Física, Universidad de las Américas, Concepción 4030000, Chile.
  • Ulloa-Díaz D; Department of Sports Sciences and Physical Conditioning, Universidad Católica de la Santísima Concepción, Concepción 4030000, Chile.
  • Alfaro Castillo B; Facultad de Educación, Universidad de Atacama, Copiapó 1531772, Chile.
  • Arroyo-Jofré P; Facultad de Educación, Universidad San Sebastián, Santiago 8420524, Chile.
  • Castillo-Paredes A; Grupo AFySE, Investigación en Actividad Física y Salud Escolar, Escuela de Pedagogía en Educación Física, Facultad de Educación, Universidad de las Américas, Santiago 8370040, Chile.
  • Chirosa-Ríos L; Department of Physical Education and Sport, Faculty of Sport Sciences, University of Granada, 18011 Granada, Spain.
Sports (Basel) ; 12(7)2024 Jun 26.
Article en En | MEDLINE | ID: mdl-39058066
ABSTRACT
The purpose of the study was to analyze the test-retest reliability of an isometric and isometric/vibratory muscular strength protocol in the bilateral seated bench press (BSBP), bilateral seated rowing (BSR), unilateral seated right knee extension (USKER), and left knee extension (USKEL) tests controlled using functional electromechanical dynamometry (FEMD) in healthy young adults. A repeated measures design was used to determine the reliability of a muscular strength protocol in isometric and isometric vibration modes with FEMD. No significant differences were found in test-retest analysis (p > 0.05; ES < 0.20); and high reliability (CV = 4.65-5.02%; ICC = 0.99-0.98) was found for BSBP measures, and acceptable reliability (CV = 3.71-9.61%; ICC = 0.98-0.95) was found for BSR, USKER, and USKEL. Furthermore, the coefficients between the two measures were strong (r = 0.963-0.839) and highly significant (p = 0.001) for maximal strength in the isometric and maximal isometric/vibratory assessment of muscle strength in all muscle strength tests. This study demonstrates that isometric and maximal isometric/vibratory strength in the BSBP, BSR, USKER, and USKEL tests can be measured with high reliability and reproducibility using the FEMD.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sports (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Chile Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sports (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Chile Pais de publicación: Suiza