Your browser doesn't support javascript.
loading
Accuracy of glomerular filtration rate estimation using creatinine and cystatin C for identifying and monitoring moderate chronic kidney disease: the eGFR-C study.
Lamb, Edmund J; Barratt, Jonathan; Brettell, Elizabeth A; Cockwell, Paul; Dalton, R Nei; Deeks, Jon J; Eaglestone, Gillian; Pellatt-Higgins, Tracy; Kalra, Philip A; Khunti, Kamlesh; Loud, Fiona C; Ottridge, Ryan S; Potter, Aisling; Rowe, Ceri; Scandrett, Katie; Sitch, Alice J; Stevens, Paul E; Sharpe, Claire C; Shinkins, Bethany; Smith, Alison; Sutton, Andrew J; Taal, Maarten W.
Afiliación
  • Lamb EJ; Clinical Biochemistry, East Kent Hospitals University NHS Foundation Trust, Canterbury, UK.
  • Barratt J; Department of Cardiovascular Sciences, University of Leicester, Leicester, UK.
  • Brettell EA; Birmingham Clinical Trials Unit, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
  • Cockwell P; Renal Medicine, Queen Elizabeth Hospital Birmingham and Institute of Inflammation and Ageing, University of Birmingham, Birmingham, UK.
  • Dalton RN; WellChild Laboratory, Evelina London Children's Hospital, St. Thomas' Hospital, London, UK.
  • Deeks JJ; Birmingham Clinical Trials Unit, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
  • Eaglestone G; Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
  • Pellatt-Higgins T; NIHR Birmingham Biomedical Research Centre, University of Birmingham and University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
  • Kalra PA; Kent Kidney Care Centre, East Kent Hospitals University NHS Foundation Trust, Kent, UK.
  • Khunti K; Centre for Health Services Studies, University of Kent, Canterbury, UK.
  • Loud FC; Department of Renal Medicine, Salford Royal Hospital Northern Care Alliance NHS Foundation Trust, Salford, UK.
  • Ottridge RS; Diabetes Research Centre, University of Leicester, Leicester, UK.
  • Potter A; Kidney Care UK, Alton, UK.
  • Rowe C; Birmingham Clinical Trials Unit, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
  • Scandrett K; Clinical Biochemistry, East Kent Hospitals University NHS Foundation Trust, Canterbury, UK.
  • Sitch AJ; Clinical Biochemistry, East Kent Hospitals University NHS Foundation Trust, Canterbury, UK.
  • Stevens PE; Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
  • Sharpe CC; Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
  • Shinkins B; NIHR Birmingham Biomedical Research Centre, University of Birmingham and University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.
  • Smith A; Kent Kidney Care Centre, East Kent Hospitals University NHS Foundation Trust, Kent, UK.
  • Sutton AJ; Faculty of Life Sciences and Medicine, King's College London, London, UK.
  • Taal MW; Academic Unit of Health Economics, Leeds Institute of Health Sciences, University of Leeds, Leeds, UK.
Health Technol Assess ; 28(35): 1-169, 2024 07.
Article en En | MEDLINE | ID: mdl-39056437
ABSTRACT

Background:

Estimation of glomerular filtration rate using equations based on creatinine is widely used to manage chronic kidney disease. In the UK, the Chronic Kidney Disease Epidemiology Collaboration creatinine equation is recommended. Other published equations using cystatin C, an alternative marker of kidney function, have not gained widespread clinical acceptance. Given higher cost of cystatin C, its clinical utility should be validated before widespread introduction into the NHS.

Objectives:

Primary objectives were to (1) compare accuracy of glomerular filtration rate equations at baseline and longitudinally in people with stage 3 chronic kidney disease, and test whether accuracy is affected by ethnicity, diabetes, albuminuria and other characteristics; (2) establish the reference change value for significant glomerular filtration rate changes; (3) model disease progression; and (4) explore comparative cost-effectiveness of kidney disease monitoring strategies.

Design:

A longitudinal, prospective study was designed to (1) assess accuracy of glomerular filtration rate equations at baseline (n = 1167) and their ability to detect change over 3 years (n = 875); (2) model disease progression predictors in 278 individuals who received additional measurements; (3) quantify glomerular filtration rate variability components (n = 20); and (4) develop a measurement model analysis to compare different monitoring strategy costs (n = 875).

Setting:

Primary, secondary and tertiary care.

Participants:

Adults (≥ 18 years) with stage 3 chronic kidney disease.

Interventions:

Estimated glomerular filtration rate using the Chronic Kidney Disease Epidemiology Collaboration and Modification of Diet in Renal Disease equations. Main outcome

measures:

Measured glomerular filtration rate was the reference against which estimating equations were compared with accuracy being expressed as P30 (percentage of values within 30% of reference) and progression (variously defined) studied as sensitivity/specificity. A regression model of disease progression was developed and differences for risk factors estimated. Biological variation components were measured and the reference change value calculated. Comparative costs of monitoring with different estimating equations modelled over 10 years were calculated.

Results:

Accuracy (P30) of all equations was ≥ 89.5% the combined creatinine-cystatin equation (94.9%) was superior (p < 0.001) to other equations. Within each equation, no differences in P30 were seen across categories of age, gender, diabetes, albuminuria, body mass index, kidney function level and ethnicity. All equations showed poor (< 63%) sensitivity for detecting patients showing kidney function decline crossing clinically significant thresholds (e.g. a 25% decline in function). Consequently, the additional cost of monitoring kidney function annually using a cystatin C-based equation could not be justified (incremental cost per patient over 10 years = £43.32). Modelling data showed association between higher albuminuria and faster decline in measured and creatinine-estimated glomerular filtration rate. Reference change values for measured glomerular filtration rate (%, positive/negative) were 21.5/-17.7, with lower reference change values for estimated glomerular filtration rate.

Limitations:

Recruitment of people from South Asian and African-Caribbean backgrounds was below the study target. Future work Prospective studies of the value of cystatin C as a risk marker in chronic kidney disease should be undertaken.

Conclusions:

Inclusion of cystatin C in glomerular filtration rate-estimating equations marginally improved accuracy but not detection of disease progression. Our data do not support cystatin C use for monitoring of glomerular filtration rate in stage 3 chronic kidney disease. Trial registration This trial is registered as ISRCTN42955626.

Funding:

This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref 11/103/01) and is published in full in Health Technology Assessment; Vol. 28, No. 35. See the NIHR Funding and Awards website for further award information.
Chronic kidney disease, which affects approximately 14% of the adult population, often has no symptoms but, in some people, may later develop into kidney failure. Kidney disease is most often detected using a blood test called creatinine. Creatinine does not identify everyone with kidney disease, or those most likely to develop more serious kidney disease. An alternative blood test called cystatin C may be more accurate, but it is more expensive than the creatinine test. We compared the accuracy of these two tests in more than 1000 people with moderate kidney disease. Participants were tested over 3 years to see if the tests differed in their ability to detect worsening kidney function. We also wanted to identify risk factors associated with loss of kidney function, and how much the tests normally vary to better understand what results mean. We compared the accuracy and costs of monitoring people with the two markers. Cystatin C was found slightly more accurate than the creatinine test at estimating kidney function when comparing the baseline single measurements (95% accurate compared to 90%), but not at detecting worsening function over time. This means that the additional cost of monitoring people over time with cystatin C to detect kidney disease progression could not be justified. Kidney test results could vary by up to 20% between tests without necessarily implying changes in underlying kidney function ­ this is the normal level of individual variation. Cystatin C marginally improved accuracy of kidney function testing but not ability to detect worsening kidney function. Cystatin C improves identification of moderate chronic kidney disease, but our results do not support its use for routine monitoring of kidney function in such patients.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Progresión de la Enfermedad / Creatinina / Insuficiencia Renal Crónica / Cistatina C / Tasa de Filtración Glomerular Límite: Adult / Aged / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Health Technol Assess Asunto de la revista: PESQUISA EM SERVICOS DE SAUDE / TECNOLOGIA MEDICA Año: 2024 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Progresión de la Enfermedad / Creatinina / Insuficiencia Renal Crónica / Cistatina C / Tasa de Filtración Glomerular Límite: Adult / Aged / Female / Humans / Male / Middle aged País/Región como asunto: Europa Idioma: En Revista: Health Technol Assess Asunto de la revista: PESQUISA EM SERVICOS DE SAUDE / TECNOLOGIA MEDICA Año: 2024 Tipo del documento: Article Pais de publicación: Reino Unido