A new sol-gel fluorescent sensor to track carbonyl compounds.
Carballido, Laura; Bou-Maroun, Elias; Weber, Guy; Bezverkhyy, Igor; Karbowiak, Thomas.
Afiliación
  • Carballido L; Univ. Bourgogne Franche-Comté, Institut Agro, Univ. de Bourgogne, INRAE, UMR PAM 1517, 1 Esplanade Erasme, 21000, Dijon, France.
  • Bou-Maroun E; Univ. Bourgogne Franche-Comté, Institut Agro, Univ. de Bourgogne, INRAE, UMR PAM 1517, 1 Esplanade Erasme, 21000, Dijon, France.
  • Weber G; Laboratoire Interdisciplinaire Carnot de Bourgogne, UMR 6303 CNRS-Université de Bourgogne Franche-Comté, 9 avenue Alain Savary, BP 47870, 21078, Dijon, Cedex, France.
  • Bezverkhyy I; Laboratoire Interdisciplinaire Carnot de Bourgogne, UMR 6303 CNRS-Université de Bourgogne Franche-Comté, 9 avenue Alain Savary, BP 47870, 21078, Dijon, Cedex, France.
  • Karbowiak T; Univ. Bourgogne Franche-Comté, Institut Agro, Univ. de Bourgogne, INRAE, UMR PAM 1517, 1 Esplanade Erasme, 21000, Dijon, France. Electronic address: thomas.karbowiak@institut-agro.fr.
Talanta ; 279: 126569, 2024 Nov 01.
Article en En | MEDLINE | ID: mdl-39042961
ABSTRACT
Carbonyl compounds are ubiquitous quality trackers that provide information about food product degradation as well as air and water pollution levels. In addition, they are used as biomarkers for medical diagnoses. With more user-friendly sensors, their fast detection and easy quantification are highly relevant. The synthesis, characterization, and performance assessment of a new sensor based on aniline fluorescence to monitor carbonyls in real time is reported. A cost-effective synthesis using a straightforward sol-gel process led to the construction of a nontoxic silica-based material with high porosity, which can be used with almost no sample preparation. The material exhibits a rapid (< 1 min) fluorescence decrease upon interaction with carbonyl groups. The limit of detection is as low as ca. 5 × 10-4 mol·L-1 for hexanal, while fluorescence extinction occurs at much higher concentrations (5 × 10-1·mol L-1), which enables the sensor to be used with a very broad range of detection. Real-time monitoring is possible since the fluorescence loss correlates with the concentration of carbonyl moieties. The performance was validated in simulating as well as in real media, making this sensor suitable for use in a wide range of applications.