Bringing online adaptive radiotherapy to a standard C-arm linac.
Groot Koerkamp, Maureen L; Bol, Gijsbert H; Kroon, Petra S; Krikke, Lean L; Harderwijk, Tessa; Zoetelief, Annelies J; Scheeren, Annick; van der Vegt, Stefan; Plat, Annika; Hes, Jochem; van Gasteren, Ineke B A; Renders, Esmee R T; Rutgers, Reijer H A; Kok, Saskia W; van Kaam, Joost; Schimmel-de Kogel, Geja J; Sikkes, Gonda G; Winkel, Dennis; van Rijssel, Michael J; Wopereis, André J M; Ishakoglu, Kübra; Noteboom, Juus L; van der Voort van Zyp, Jochem R N; Beck, Naomi; Soeterik, Timo F W; van de Pol, Sandrine M G; Eppinga, Wietse S C; van Es, Corine A; Raaymakers, Bas W.
Afiliación
  • Groot Koerkamp ML; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Bol GH; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Kroon PS; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Krikke LL; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Harderwijk T; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Zoetelief AJ; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Scheeren A; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • van der Vegt S; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Plat A; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Hes J; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • van Gasteren IBA; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Renders ERT; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Rutgers RHA; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Kok SW; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • van Kaam J; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Schimmel-de Kogel GJ; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Sikkes GG; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Winkel D; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • van Rijssel MJ; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Wopereis AJM; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Ishakoglu K; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Noteboom JL; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • van der Voort van Zyp JRN; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Beck N; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Soeterik TFW; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • van de Pol SMG; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Eppinga WSC; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • van Es CA; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
  • Raaymakers BW; Department of Radiotherapy, UMC Utrecht, Heidelberglaan 100, 3584CX Utrecht, the Netherlands.
Phys Imaging Radiat Oncol ; 31: 100597, 2024 Jul.
Article en En | MEDLINE | ID: mdl-39006756
ABSTRACT
Current online adaptive radiotherapy (oART) workflows require dedicated equipment. Our aim was to develop and implement an oART workflow for a C-arm linac which can be performed using standard clinically available tools. A workflow was successfully developed and implemented. Three patients receiving palliative radiotherapy for bladder cancer were treated, with 33 of 35 total fractions being delivered with the cone-beam computed tomography (CBCT)-guided oART workflow. Average oART fraction duration was 24 min from start of CBCT acquisition to end of beam on. This work shows how oART could be performed without dedicated equipment, broadening oART availability for application at existing treatment machines.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Phys Imaging Radiat Oncol Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Países Bajos