A Comparative Evaluation of Frictional Resistance of Various Lingual Brackets With Nitinol (NiTi) Archwires of Different Dimensions: An In Vitro Study.
Ranjan Padhi, Soumya; Gaikwad, Shashank; Ranjan, Alok; Gangurde, Parag V; Mishra, Harsh.
Afiliación
  • Ranjan Padhi S; Department of Orthodontics and Dentofacial Orthopedics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Navi Mumbai, IND.
  • Gaikwad S; Department of Orthodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Navi Mumbai, IND.
  • Ranjan A; Department of Orthodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Navi Mumbai, IND.
  • Gangurde PV; Department of Orthodontics and Dentofacial Orthopedics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Navi Mumbai, IND.
  • Mishra H; Department of Orthodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Navi Mumbai, IND.
Cureus ; 16(6): e62121, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38993465
ABSTRACT
Introduction Orthodontic mechanics involves transferring some of the applied force to the tooth's supporting components via friction, which in turn allows the tooth to move more easily. Aim The purpose of this in vitro experiment was to examine the frictional resistance (FR) of different lingual brackets utilizing Instron universal testing machines and nitinol (NiTi) archwires of varying sizes. Materials and methods Twenty-four sectional anterior die stones were replicated from a study model. They were categorized into eight categories, with the Libral lingual bracket and the JJ lingual bracket having 0.012" and 0.014" inch NiTi archwire, which were further subdivided into six subgroups. Three brackets were bonded to the anterior teeth of the upper and lower segments and replicated on other models with the help of silicon putty. Elastomeric modules were ligated to two diameters of NiTi wire (0.012" and 0.014") in each model. An Instron universal testing machine was used to measure the frictional force. Numerical data and descriptive statistics such as mean and standard deviation have been shown. Results In the overall analysis, it was observed that among JJ Orthodontics samples using 0.012" NiTi archwires, the maxilla exhibited a higher FR (4.205N) compared to the mandible (4.092N). Similarly, in the case of Libral Orthodontics samples with 0.012" NiTi archwires, the maxilla also demonstrated a higher FR (5.10N) than the mandible (4.97N). However, this trend did not hold for samples using 0.014" NiTi archwires. There was a statistically nonsignificant difference (p > 0.05) in the values between all the pairs of groups. Conclusion The present study concludes that Libral lingual brackets produced overall more FR than JJ lingual brackets.