Your browser doesn't support javascript.
loading
Evaluation of safety and operative time in tumescent-free robotic nipple-sparing mastectomy: a retrospective single-center cohort study.
Hwang, Yung-Huyn; Han, Hyun Ho; Eom, Jin Sup; Yoo, Tae-Kyung Robyn; Kim, Jisun; Chung, Il Yong; Ko, BeomSeok; Kim, Hee Jeong; Lee, Jong Won; Son, Byung Ho; Lee, Sae Byul.
Afiliación
  • Hwang YH; Department of Surgery, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Korea.
  • Han HH; Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Eom JS; Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Yoo TR; Division of Breast Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Kim J; Division of Breast Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Chung IY; Division of Breast Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Ko B; Division of Breast Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Kim HJ; Division of Breast Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Lee JW; Division of Breast Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Son BH; Division of Breast Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Lee SB; Division of Breast Surgery, Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Ann Surg Treat Res ; 107(1): 8-15, 2024 Jul.
Article en En | MEDLINE | ID: mdl-38978689
ABSTRACT

Purpose:

Tumescent in nipple-sparing mastectomy (NSM) has been reported to increase the risk of necrosis by impairing blood flow to the skin flap and nipple-areolar complex. At our institution, we introduced a tumescent-free robotic NSM using the da Vinci single-port system (Intuitive Surgical, Inc.).

Methods:

We conducted a retrospective analysis of patients who underwent tumescent-free robotic NSM between October 2020 and March 2023 at Asan Medical Center (Seoul, Korea). Clinicopathological characteristics, adverse events, and operative time were evaluated.

Results:

During the study period, 118 patients underwent tumescent-free robotic NSM. Thirty-one patients (26.3%) experienced an adverse event. Five patients (4.2%) were classified as grade III based on the Clavien-Dindo classification and required surgery. The mean total operative time was 467 minutes for autologous tissue reconstruction (n = 49) and 252 minutes for implants (n = 69). No correlation was found between the cumulative number of surgical cases and the breast operative time (P = 0.30, 0.52, 0.59 for surgeons A, B, C) for the 3 surgeons. However, a significant linear relationship (P < 0.001) was observed, with the operative time increasing by 13 minutes for every 100-g increase in specimen weight.

Conclusion:

Tumescent-free robotic NSM is a safe procedure with a feasible operative time and few adverse events.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Ann Surg Treat Res Año: 2024 Tipo del documento: Article Pais de publicación:

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Ann Surg Treat Res Año: 2024 Tipo del documento: Article Pais de publicación: