Your browser doesn't support javascript.
loading
Miniaturizable Chemiluminescence System for ATP Detection in Water.
Capuano, Giuseppe E; Corso, Domenico; Farina, Roberta; Pezzotti Escobar, Gianni; Screpis, Giuseppe A; Coniglio, Maria Anna; Libertino, Sebania.
Afiliación
  • Capuano GE; Istituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.
  • Corso D; Istituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.
  • Farina R; Istituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.
  • Pezzotti Escobar G; Department of Chemical Sciences, University of Catania, Viale Andrea Doria 6, 95125 Catania, Italy.
  • Screpis GA; URT "LabSens of Beyond Nano" of the Department of Physical Sciences and Technologies of Matter, National Research Council (CNR-DSFTM-ME), Viale Ferdinando Stagno D'Alcontres 31, 98166 Messina, Italy.
  • Coniglio MA; Department of Medical, Surgical Sciences and Advanced Technologies, University of Catania, Via S. Sofia 78, 95123 Catania, Italy.
  • Libertino S; Istituto per la Microeletttronica e Microsistemi-Consiglio Nazionale delle Ricerche, VIII Strada Z.I., 5, 95121 Catania, Italy.
Sensors (Basel) ; 24(12)2024 Jun 17.
Article en En | MEDLINE | ID: mdl-38931704
ABSTRACT
We present the design, fabrication, and testing of a low-cost, miniaturized detection system that utilizes chemiluminescence to measure the presence of adenosine triphosphate (ATP), the energy unit in biological systems, in water samples. The ATP-luciferin chemiluminescent solution was faced to a silicon photomultiplier (SiPM) for highly sensitive real-time detection. This system can detect ATP concentrations as low as 0.2 nM, with a sensitivity of 79.5 A/M. Additionally, it offers rapid response times and can measure the characteristic time required for reactant diffusion and mixing within the reaction volume, determined to be 0.3 ± 0.1 s. This corresponds to a diffusion velocity of approximately 44 ± 14 mm2/s.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Agua / Adenosina Trifosfato / Mediciones Luminiscentes Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Agua / Adenosina Trifosfato / Mediciones Luminiscentes Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Suiza