Your browser doesn't support javascript.
loading
Proton 3D dose measurement with a multi-layer strip ionization chamber (MLSIC) device.
Zhou, Shuang; Chen, Qinghao; Haefner, Jonathan; Smith, Winter; Darafsheh, Arash; Zhao, Tianyu; Harrison, Nathan Andrew; Zhou, Jun; Lin, Liyong; Lu, Weiguo; Shen, Liuxing; Jiang, Hao; Zhang, Tiezhi.
Afiliación
  • Zhou S; Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63108, United States of America.
  • Chen Q; Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63108, United States of America.
  • Haefner J; Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63108, United States of America.
  • Smith W; Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63108, United States of America.
  • Darafsheh A; Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63108, United States of America.
  • Zhao T; Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63108, United States of America.
  • Harrison NA; Emory Proton Therapy Center, Atlanta, GA 30308, United States of America.
  • Zhou J; Emory Proton Therapy Center, Atlanta, GA 30308, United States of America.
  • Lin L; Emory Proton Therapy Center, Atlanta, GA 30308, United States of America.
  • Lu W; Unversity of Texas, Southwestern, Dallas, TX 75390, United States of America.
  • Shen L; TetraImaging LLC, Maryland Heights, MO 63043, United States of America.
  • Jiang H; TetraImaging LLC, Maryland Heights, MO 63043, United States of America.
  • Zhang T; Department of Radiation Oncology, Physics Division, Washington University in St. Louis School of Medicine, St. Louis, MO 63108, United States of America.
Phys Med Biol ; 69(13)2024 Jun 26.
Article en En | MEDLINE | ID: mdl-38843812
ABSTRACT
Objective. In current clinical practice for quality assurance (QA), intensity modulated proton therapy (IMPT) fields are verified by measuring planar dose distributions at one or a few selected depths in a phantom. A QA device that measures full 3D dose distributions at high spatiotemporal resolution would be highly beneficial for existing as well as emerging proton therapy techniques such as FLASH radiotherapy. Our objective is to demonstrate feasibility of 3D dose measurement for IMPT fields using a dedicated multi-layer strip ionization chamber (MLSIC) device.Approach.Our developed MLSIC comprises a total of 66 layers of strip ion chamber (IC) plates arranged, alternatively, in thexandydirection. The first two layers each has 128 channels in 2 mm spacing, and the following 64 layers each has 32/33 IC strips in 8 mm spacing which are interconnected every eight channels. A total of 768-channel IC signals are integrated and sampled at a speed of 6 kfps. The MLSIC has a total of 19.2 cm water equivalent thickness and is capable of measurement over a 25 × 25 cm2field size. A reconstruction algorithm is developed to reconstruct 3D dose distribution for each spot at all depths by considering a double-Gaussian-Cauchy-Lorentz model. The 3D dose distribution of each beam is obtained by summing all spots. The performance of our MLSIC is evaluated for a clinical pencil beam scanning (PBS) plan.Main results.The dose distributions for each proton spot can be successfully reconstructed from the ionization current measurement of the strip ICs at different depths, which can be further summed up to a 3D dose distribution for the beam. 3D Gamma Index analysis indicates acceptable agreement between the measured and expected dose distributions from simulation, Zebra and MatriXX.Significance.The dedicated MLSIC is the first pseudo-3D QA device that can measure 3D dose distribution in PBS proton fields spot-by-spot.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radiometría / Terapia de Protones Límite: Humans Idioma: En Revista: Phys Med Biol Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Radiometría / Terapia de Protones Límite: Humans Idioma: En Revista: Phys Med Biol Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido