Your browser doesn't support javascript.
loading
Development of a 3D-printed nuchal translucency model: a pilot study for prenatal ultrasound training.
Recker, Florian; Remmersmann, Laura; Jost, Elena; Jimenez-Cruz, Jorge; Haverkamp, Nicolas; Gembruch, Ulrich; Strizek, Brigitte; Schäfer, Valentin S.
Afiliación
  • Recker F; Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany. florian.recker@ukbonn.de.
  • Remmersmann L; Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany.
  • Jost E; Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany.
  • Jimenez-Cruz J; Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany.
  • Haverkamp N; Office of Academic Affairs, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany.
  • Gembruch U; Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany.
  • Strizek B; Department of Obstetrics and Prenatal Medicine, University Hospital Bonn, Venusberg Campus 1, 53127, Bonn, Germany.
  • Schäfer VS; Department of Rheumatology and Clinical Immunology, Clinic of Internal Medicine III, University Hospital Bonn, Bonn, Germany.
Arch Gynecol Obstet ; 310(4): 2055-2064, 2024 10.
Article en En | MEDLINE | ID: mdl-38796557
ABSTRACT

BACKGROUND:

We used two 3D ultrasound volumes of fetal heads at 13 weeks to create live-size 3D-printed phantoms with a view to training or assessment of diagnostic abilities for normal and abnormal nuchal translucency measurements. The phantoms are suitable for use in a water bath, imitating a real-life exam. They were then used to study measurement accuracy and reproducibility in examiners of different skill levels.

METHODS:

Ultrasound scans of a 13 + 0-week fetus were processed using 3D Slicer software, producing a stereolithography file for 3D printing. The model, crafted in Autodesk Fusion360™, adhered to FMF guidelines for NT dimensions (NT 2.3 mm). Additionally, a model with pathologic NT was designed (NT 4.2 mm). Printing was performed via Formlabs Form 3® printer using High Temp Resin V2. The externally identical looking 3D models were embedded in water-filled condoms for ultrasound examination. Eight specialists of varying expertise levels conducted five NT measurements for each model, classifying them in physiological and abnormal models.

RESULTS:

Classification of the models in physiological or abnormal NT resulted in a detection rate of 100%. Average measurements for the normal NT model and the increased NT model were 2.27 mm (SD ± 0.38) and 4.165 mm (SD ± 0.51), respectively. The interrater reliability was calculated via the intraclass correlation coefficient (ICC) which yielded a result of 0.883, indicating robust agreement between the raters. Cost-effectiveness analysis demonstrated the economical nature of the 3D printing process.

DISCUSSION:

This study underscores the potential of 3D printed fetal models for enhancing ultrasound training through high inter-rater reliability, consistency across different expert levels, and cost-effectiveness. Limitations, including population variability and direct translation to clinical outcomes, warrant further exploration. The study contributes to ongoing discussions on integrating innovative technologies into medical education, offering a practical and economical method to acquire, refine and revise diagnostic skills in prenatal ultrasound. Future research should explore broader applications and long-term economic implications, paving the way for transformative advancements in medical training and practice.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Medida de Translucencia Nucal / Impresión Tridimensional Límite: Female / Humans / Pregnancy Idioma: En Revista: Arch Gynecol Obstet Asunto de la revista: GINECOLOGIA / OBSTETRICIA Año: 2024 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Medida de Translucencia Nucal / Impresión Tridimensional Límite: Female / Humans / Pregnancy Idioma: En Revista: Arch Gynecol Obstet Asunto de la revista: GINECOLOGIA / OBSTETRICIA Año: 2024 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Alemania