Your browser doesn't support javascript.
loading
A quantitative assessment of Geant4 for predicting the yield and distribution of positron-emitting fragments in ion beam therapy.
Chacon, Andrew; Rutherford, Harley; Hamato, Akram; Nitta, Munetaka; Nishikido, Fumihiko; Iwao, Yuma; Tashima, Hideaki; Yoshida, Eiji; Akamatsu, Go; Takyu, Sodai; Kang, Han Gyu; Franklin, Daniel R; Parodi, Katia; Yamaya, Taiga; Rosenfeld, Anatoly; Guatelli, Susanna; Safavi-Naeini, Mitra.
Afiliación
  • Chacon A; Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW, Australia.
  • Rutherford H; Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW, Australia.
  • Hamato A; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Nitta M; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Nishikido F; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Iwao Y; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Tashima H; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Yoshida E; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Akamatsu G; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Takyu S; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Kang HG; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Franklin DR; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Parodi K; School of Electrical and Data Engineering, University of Technology Sydney, Ultimo, Australia.
  • Yamaya T; Department of Medical Physics, Faculty of Physics, Garching b, Ludwig-Maximilians-Universität München, Munich, Germany.
  • Rosenfeld A; National Institutes for Quantum Science and Technology, Chiba, Japan.
  • Guatelli S; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Safavi-Naeini M; Illawarra Health and Medical Research Institute, University of Wollongong, Wollongong, NSW 2522, Australia.
Phys Med Biol ; 69(12)2024 Jun 11.
Article en En | MEDLINE | ID: mdl-38776943
ABSTRACT
Objective.To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy.Approach.Phantoms of polyethylene, gelatin, or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion beams. Post-irradiation, 4D PET images were acquired and parent11C,10C and15O radionuclides contributions in each voxel were determined from the extracted time activity curves. Next, the experimental configurations were simulated in Geant4 Monte Carlo versions 10.0 to 11.1, with three different fragmentation models-binary ion cascade (BIC), quantum molecular dynamics (QMD) and the Liege intranuclear cascade (INCL++) - 30 model-version combinations. Total positron annihilation and parent isotope production yields predicted by each simulation were compared between simulations and experiments using normalised mean squared error and Pearson cross-correlation coefficient. Finally, we compared the depth of the maximum positron annihilation yield and the distal point at which the positron yield decreases to 50% of peak between each model and the experimental results.Main results.Performance varied considerably across versions and models, with no one version/model combination providing the best prediction of all positron-emitting fragments in all evaluated target materials and irradiation conditions. BIC in Geant4 10.2 provided the best overall agreement with experimental results in the largest number of test cases. QMD consistently provided the best estimates of both the depth of peak positron yield (10.4 and 10.6) and the distal 50%-of-peak point (10.2), while BIC also performed well and INCL generally performed the worst across most Geant4 versions.Significance.The best predictions of the spatial distribution of positron annihilations and positron-emitting fragment production along the beam path during carbon and oxygen ion therapy was obtained using Geant4 10.2.p03 with BIC or QMD. These version/model combinations are recommended for future heavy ion therapy research.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Método de Montecarlo Idioma: En Revista: Phys Med Biol Año: 2024 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Método de Montecarlo Idioma: En Revista: Phys Med Biol Año: 2024 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Reino Unido