Your browser doesn't support javascript.
loading
Femorotibial rotation is linearly associated with tibial tubercle-trochlear groove distance: A cadaveric study.
Pascual-Leone, Nicolas; Jahandar, Amirhossein; Davie, Ryann; Bram, Joshua T; Chipman, Danielle E; Imhauser, Carl W; Green, Daniel W.
Afiliación
  • Pascual-Leone N; Pediatric Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA. Electronic address: pascualleonen@hss.edu.
  • Jahandar A; Biomechanics Research, Hospital for Special Surgery, New York, NY, USA. Electronic address: jahandara@hss.edu.
  • Davie R; Pediatric Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA. Electronic address: davier@hss.edu.
  • Bram JT; Pediatric Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA. Electronic address: bramj@hss.edu.
  • Chipman DE; Pediatric Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA. Electronic address: chipmand@hss.edu.
  • Imhauser CW; Biomechanics Research, Hospital for Special Surgery, New York, NY, USA. Electronic address: imhauserc@hss.edu.
  • Green DW; Pediatric Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA. Electronic address: greendw@hss.edu.
J ISAKOS ; 9(4): 598-602, 2024 Aug.
Article en En | MEDLINE | ID: mdl-38735371
ABSTRACT

OBJECTIVES:

A tibial tubercle-trochlear groove (TT-TG) distance of 20 millimeters (mm) is typically used when determining whether tibial tubercle medialization is performed for the surgical treatment of patellar instability. Without knowledge of how the variability of an individual's TT-TG distance is influenced by through-the-knee femorotibial rotation, the use of a specific TT-TG distance during preoperative planning for patellar instability may lead to incorrect decisions on the use of tibial tubercle medialization. We hypothesized that knee joint internal/external (IE) rotation is related to the TT-TG distance.

METHODS:

Eight independent human cadaveric knee specimens (age 32 â€‹± â€‹6 years; 4 males, 4 females) were utilized. A robotic manipulator (ZX165U, Kawasaki Robotics, Wixom, MI, USA) instrumented with a universal force/moment sensor was used to determine knee joint IE rotation under applied moments of ±5 newton-meters (Nm) at full extension. Two independent reviewers selected the trochlear groove and tibial tuberosity points on computerized tomography (CT) images of each specimen to define TT-TG. To determine the influence of knee joint IE rotation on TT-TG distance, three-dimensional (3D) models generated from CT scans were registered to tibiofemoral kinematics. Linear regression was performed to determine the relationship between knee joint IE rotation and TT-TG distance. The regression coefficient, standard error of measurement (α â€‹= â€‹0.05), and coefficient of determination (r2) were reported.

RESULTS:

At 0° of rotation, the mean TT-TG distance was 14.2 â€‹± â€‹5.0 â€‹mm. Knee joint IE rotation averaged 23.0 â€‹± â€‹4.2°. For every degree of knee joint IE rotation, TT-TG distance changed by 0.52 â€‹mm.

CONCLUSION:

TT-TG distance was linearly dependent on knee joint IE rotation, changing by 0.52 â€‹mm for every degree of knee joint IE rotation. Thus, an offset of IE rotation of 10° would lead to a change in TT-TG distance of 5.2 â€‹mm, enough to alter the surgical decision-making for/or against tibial tubercle medialization. LEVEL OF EVIDENCE IV This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tibia / Cadáver / Fémur / Articulación de la Rodilla Límite: Adult / Female / Humans / Male Idioma: En Revista: J ISAKOS Año: 2024 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Tibia / Cadáver / Fémur / Articulación de la Rodilla Límite: Adult / Female / Humans / Male Idioma: En Revista: J ISAKOS Año: 2024 Tipo del documento: Article Pais de publicación: Reino Unido