Totally Endoscopic Replacement of the Ascending Aorta and the Aortic Root including the Aortic Valve via Right Mini-Thoracotomy: A Multicenter Study.
J Clin Med
; 13(9)2024 Apr 30.
Article
en En
| MEDLINE
| ID: mdl-38731177
ABSTRACT
Background:
Recently, minimally invasive access via right anterolateral mini-thoracotomy (RAMT) has been gaining popularity in cardiac surgery. This approach is also an option for surgeons performing aortic surgery. The aim of this study is to present our surgical method, highlighting the total endoscopic minimally invasive approach via RAMT for replacement of the ascending aorta (AAR) with or without involvement of the aortic root and the aortic valve.Methods:
Clinical data of 44 patients from three participating institutions with AAR with or without involvement of the aortic valve or aortic root via RAMT between April 2017 and February 2024 were retrospectively analyzed. According to surgical procedure, patients were divided into two groups, in the AAR and in the Wheat/Bentall group with concomitant valve or root replacement. Operative time, length of ventilation, perioperative outcome, length of intensive care unit (ICU) as well as postoperative hospital stay, and mid- and long-term results were retrospectively analyzed.Results:
Mean age was 61.4 ± 10.7 years old with a frequency of male gender of 63.6%. Mean cardiopulmonary bypass (CBP) time and aortic cross-clamping time was 94.9 ± 32.5 min and 63.8 ± 25.9 min, respectively. CPB and aortic clamp time were significantly lower in AAR group. In the first 24 h, the mean drainage volume was 790.3 ± 423.6 mL. Re-thoracotomy due to bleeding was zero. Sternotomy was able to be avoided in all patients. Patients stayed 35.9 ± 23.5 h at ICU and were discharged 7.8 ± 3.0 days following surgery from hospital. Mean ventilation time was 5.8 ± 7.6 h. All patients survived and 30-day mortality was 0.0%. At a median follow-up time of 18.2 months, all patients were alive. The results were similar in both groups.Conclusions:
The full endoscopic RAMT approach with 3D visualization is a safe, feasible and promising technique that can be transferred in the field of aortic surgery without compromising surgical quality, postoperative outcomes, or patient safety when performed by an experienced team in a high-volume center.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Idioma:
En
Revista:
J Clin Med
Año:
2024
Tipo del documento:
Article
País de afiliación:
Alemania
Pais de publicación:
Suiza