Your browser doesn't support javascript.
loading
Ultrasound image denoising autoencoder model based on lightweight attention mechanism.
Shi, Liuliu; Di, Wentao; Liu, Jinlong.
Afiliación
  • Shi L; School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, China.
  • Di W; Key Laboratory of Power Machinery and Engineering of Ministry of Education, Shanghai Jiao Tong University, Shanghai, China.
  • Liu J; Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering, Shanghai, China.
Quant Imaging Med Surg ; 14(5): 3557-3571, 2024 May 01.
Article en En | MEDLINE | ID: mdl-38720841
ABSTRACT

Background:

The presence of noise in medical ultrasound images significantly degrades image quality and affects the accuracy of disease diagnosis. The convolutional neural network-denoising autoencoder (CNN-DAE) model extracts feature information by stacking regularly sized kernels. This results in the loss of texture detail, the over-smoothing of the image, and a lack of generalizability for speckle noise.

Methods:

A lightweight attention denoise-convolutional neural network (LAD-CNN) is proposed in the present study. Two different lightweight attention blocks (i.e., the lightweight channel attention (LCA) block and the lightweight large-kernel attention (LLA) block are concatenated into the downsampling stage and the upsampling stage, respectively. A skip connection is included before the upsampling layer to alleviate the problem of gradient vanishing during backpropagation. The effectiveness of our model was evaluated using both subjective visual effects and objective evaluation metrics.

Results:

With the highest peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) values at all noise levels, the proposed model outperformed the other models. In the test of brachial plexus ultrasound images, the average PSNR of our model was 0.15 higher at low noise levels and 0.33 higher at high noise levels than the suboptimal model. In the test of fetal ultrasound images, the average PSNR of our model was 0.23 higher at low noise levels and 0.20 higher at high noise levels than the suboptimal model. The statistical analysis showed that the p values were less than 0.05, which indicated a statistically significant difference between our model and the other models.

Conclusions:

The results of this study suggest that the proposed LAD-CNN model is more efficient in denoising and preserving image details than both conventional denoising algorithms and existing deep-learning algorithms.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Quant Imaging Med Surg Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Quant Imaging Med Surg Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: China