Maximum resistance pressure at the time of lung tissue rupture after porcine lung transection using automatic linear staplers with different reinforcement methods.
Surg Today
; 2024 May 01.
Article
en En
| MEDLINE
| ID: mdl-38691222
ABSTRACT
PURPOSES:
Polyglycolic acid (PGA) sheets, fibrin glue, and staple line reinforcement are frequently used to prevent air leakage during lung resection. However, the optimal staple-line reinforcement method remains unclear.METHODS:
Cranial lung lobes of pigs were used to evaluate different staple line reinforcement methods (n = 6). Ventilator-assisted manometry was used to measure the maximum resistance pressure at the time of rupture of the lung tissue after stapling.RESULTS:
The mean maximum resistance pressures at the time of lung tissue rupture after using the stapler alone, stapler with PGA sheet and fibrin glue, and stapler with reinforcement were 38.0 cmH2O, 51.3 cmH2O, and 62.7 cmH2O, respectively. A significant increase in the maximum resistance pressure was observed with stapler reinforcement (P < 0.001), while the differences between the other groups were not statistically significant (P = 0.055, P = 0.111). A histological assessment revealed disruption of alveolar structures near the needle-stitching site in the stapler alone, and in the stapler with PGA sheet and fibrin glue groups. Pleural rupture near the staple line was observed in the stapler with reinforcement group.CONCLUSIONS:
The maximum resistance pressure before air leakage was significantly higher when using a stapler with reinforcement than when using a stapler alone.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Idioma:
En
Revista:
Surg Today
Año:
2024
Tipo del documento:
Article
País de afiliación:
Japón
Pais de publicación:
Japón