Your browser doesn't support javascript.
loading
Increasing the efficiency of cone-beam CT based delta-radiomics using automated contours to predict radiotherapy-related toxicities in prostate cancer.
Delgadillo, Rodrigo; Deana, Anthony M; Ford, John C; Studenski, Matthew T; Padgett, Kyle R; Abramowitz, Matthew C; Pra, Alan Dal; Spieler, Benjamin O; Dogan, Nesrin.
Afiliación
  • Delgadillo R; Department of Radiation Oncology, University of Miami Miller School of Medicine, 1475 NW 12Th Ave, Miami, FL, 33136, USA.
  • Deana AM; Department of Radiation Oncology, University of Miami Miller School of Medicine, 1475 NW 12Th Ave, Miami, FL, 33136, USA.
  • Ford JC; Varian Medical Systems, Advanced Oncology Solutions, Avon, IN, USA.
  • Studenski MT; Department of Radiation Oncology, University of Miami Miller School of Medicine, 1475 NW 12Th Ave, Miami, FL, 33136, USA.
  • Padgett KR; Department of Radiation Oncology, University of Miami Miller School of Medicine, 1475 NW 12Th Ave, Miami, FL, 33136, USA.
  • Abramowitz MC; Department of Radiation Oncology, University of Miami Miller School of Medicine, 1475 NW 12Th Ave, Miami, FL, 33136, USA.
  • Pra AD; Department of Radiation Oncology, University of Miami Miller School of Medicine, 1475 NW 12Th Ave, Miami, FL, 33136, USA.
  • Spieler BO; Department of Radiation Oncology, University of Miami Miller School of Medicine, 1475 NW 12Th Ave, Miami, FL, 33136, USA.
  • Dogan N; Department of Radiation Oncology, University of Miami Miller School of Medicine, 1475 NW 12Th Ave, Miami, FL, 33136, USA.
Sci Rep ; 14(1): 9563, 2024 04 26.
Article en En | MEDLINE | ID: mdl-38671043
ABSTRACT
Extracting longitudinal image quantitative data, known as delta-radiomics, has the potential to capture changes in a patient's anatomy throughout the course of radiation treatment for prostate cancer. Some of the major challenges of delta-radiomics studies are contouring the structures for individual fractions and accruing patients' data in an efficient manner. The manual contouring process is often time consuming and would limit the efficiency of accruing larger sample sizes for future studies. The problem is amplified because the contours are often made by highly trained radiation oncologists with limited time to dedicate to research studies of this nature. This work compares the use of automated prostate contours generated using a deformable image-based algorithm to make predictive models of genitourinary and changes in total international prostate symptom score in comparison to manually contours for a cohort of fifty patients. Area under the curve of manual and automated models were compared using the Delong test. This study demonstrated that the delta-radiomics models were similar for both automated and manual delta-radiomics models.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Tomografía Computarizada de Haz Cónico Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Tomografía Computarizada de Haz Cónico Límite: Aged / Humans / Male / Middle aged Idioma: En Revista: Sci Rep Año: 2024 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido