Your browser doesn't support javascript.
loading
Clinical Outcomes of a New Hydrophobic Trifocal Intraocular Lens with Hydroxyethyl Methacrylate in Cataract Surgery: A Prospective Multicenter Study.
Jo, Eunhui; Kim, Bokyung; Kim, Tae-Im; Kim, Mee Kum; Choi, Chul Young.
Afiliación
  • Jo E; Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Kim B; Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Kim TI; Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
  • Kim MK; Corneal Dystrophy Research Institute, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.
  • Choi CY; Department of Ophthalmology, Seoul National University Hospital, Seoul National University College of Medicine, Korea.
Korean J Ophthalmol ; 38(3): 212-220, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38644651
ABSTRACT

PURPOSE:

To investigate the clinical outcomes of new hydrophobic trifocal intraocular lens with hydroxyethyl methacrylate in the Korean population.

METHODS:

This prospective, multicenter, and observational study evaluated the clinical outcomes of 80 eyes of 40 patients with age-related cataract underwent cataract surgery using CNWT (Clareon PanOptix). Assessment included monocular and binocular uncorrected distance visual acuity, corrected distance visual acuity, uncorrected intermediate visual acuity (at 60cm), near visual acuity (at 40 and 33 cm), uncorrected defocus curves, questionnaires evaluating photic phenomena, spectacle independence, and spectacle free satisfaction.

RESULTS:

At postoperative 3 months, mean uncorrected binocular visual acuities were 0.04, 0.04, 0.03 logarithm of the minimum angle of resolution (logMAR) at far, intermediate, and near distances, respectively. All patients achieved uncorrected binocular visual acuity of 0.2 logMAR or better. Monocular and binocular defocus curve indicated a mean visual acuity of 0.2 logMAR or better at the defocus range of +1.0 to - 3.0 diopters (100 to 33 cm) and +1.0 to - 3.5 diopters (100 to 28 cm). High spectacle independence was observed at all distances, with 37.5% patients reporting photic phenomena.

CONCLUSIONS:

The Clareon PanOptix intraocular lens has shown positive clinical outcomes, providing a viable option for cataract surgery. These lenses effectively address patients' visual needs, especially in intermediate and near distance tasks, reducing dependence on glasses.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Agudeza Visual Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Korean J Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2024 Tipo del documento: Article Pais de publicación: Corea del Sur

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Agudeza Visual Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Korean J Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2024 Tipo del documento: Article Pais de publicación: Corea del Sur