Higher contact pressure of the lateral tibiofemoral joint in lateral extra-articular tenodesis with tensioned graft in external rotation than in neutral rotation: A biomechanical study.
J ISAKOS
; 9(4): 562-567, 2024 Aug.
Article
en En
| MEDLINE
| ID: mdl-38636904
ABSTRACT
OBJECTIVE:
To determine the mean contact pressure, peak contact pressure, and mean contact area of the lateral tibiofemoral joint in lateral extra-articular tenodesis (LET) with tension on the graft in tibial neutral and external rotation.METHODS:
A total of eight Thiel-embalmed cadaveric knees were prepared and divided into two groups (4 knees in each group) the LET-NR group (lateral extra-articular tenodesis tension in neutral rotation) and (2) the LET-ER group (lateral extra-articular tenodesis tension in external rotation). Each knee was prepared according to the corresponding technique. A hydraulic testing system (E10000, Instron) simulates an axial load of 735 âN for 10 âs in each group.RESULTS:
The LET-ER group exhibited a statistically significant higher peak contact pressure compared to the LET-NR group. The peak contact pressure values in the LET-NR and LET-ER groups were 702.3 â± â233.9 âkPa and 1235.5 â± â171.4 âkPa, respectively (p â= â0.010, 95% CI, -888.0 to -178.5). The mean contact pressure values in the LET-NR and LET-ER groups were 344.9 â± â69.0 âkPa and 355.3 â± â34.9 âkPa, respectively (p â= â0.796, 95% CI, -105.1-84.2). The mean contact area values in the LET-NR and LET-ER groups were 36.8 â± â3.1 mm2 and 33.3 â± â6.4 mm2, respectively (p â= â0.360, 95% CI, -5.2-12.2).CONCLUSIONS:
The peak contact pressure of the lateral tibiofemoral joint is greater in LET when the graft is tensioned in external rotation than in neutral rotation. However, no statistically significant difference in the mean contact pressure or the mean contact area was observed between the two groups. LEVEL OF EVIDENCE III.Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Presión
/
Tibia
/
Tenodesis
/
Articulación Tibiofemoral
Límite:
Humans
Idioma:
En
Revista:
J ISAKOS
Año:
2024
Tipo del documento:
Article
País de afiliación:
Tailandia
Pais de publicación: