Surgical Correction of a Sinus Venosus Atrial Septal Defect with Partial Anomalous Pulmonary Venous Connections Using Cardiac Computed Tomography Imaging and a 3D-Printed Model.
Kim, Kyung-Min; Moon, Chang-Hwan; Lee, Won-Jong; Kim, Woo-Jin; Kim, Mihyung; Jeong, Jaemin; Lee, Hae-Beom; Jeong, Seong-Mok; Choi, Ho-Jung; Hwang, Tae Sung; Lee, Hee Chun; Yu, Jae Hyeon; Nam, Aryung; Kim, Dae-Hyun.
Afiliación
  • Kim KM; Department of Veterinary Surgery, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
  • Moon CH; Department of Veterinary Surgery, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
  • Lee WJ; Department of Veterinary Surgery, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
  • Kim WJ; Department of Veterinary Surgery, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
  • Kim M; Chungnam National University Sejong Hospital, 20 Bodeum 7-ro, Sejong-si 30099, Republic of Korea.
  • Jeong J; Department of Veterinary Surgery, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
  • Lee HB; Department of Veterinary Surgery, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
  • Jeong SM; Department of Veterinary Surgery, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
  • Choi HJ; Department of Veterinary Medical Imaging, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
  • Hwang TS; Institute of Animal Medicine, College of Veterinary Medicine, Gyeongsang National University, 501 Jinju-daero, Jinju-si 52828, Republic of Korea.
  • Lee HC; Institute of Animal Medicine, College of Veterinary Medicine, Gyeongsang National University, 501 Jinju-daero, Jinju-si 52828, Republic of Korea.
  • Yu JH; Department of Cardiothoracic Surgery, Chungnam National University Hospital, College of Medicine, Chungnam National University, 282 Munhwa-ro, Jung-gu, Daejeon 35015, Republic of Korea.
  • Nam A; Department of Veterinary Internal Medicine, College of Veterinary Medicine, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05029, Republic of Korea.
  • Kim DH; Department of Veterinary Surgery, College of Veterinary Medicine, Chungnam National University, 99 Daehak-ro, Yuseong-gu, Daejeon 34134, Republic of Korea.
Animals (Basel) ; 14(7)2024 Apr 03.
Article en En | MEDLINE | ID: mdl-38612332
ABSTRACT
Sinus venosus atrial septal defects (SVASDs), concurrent with partial anomalous pulmonary venous connections (PAPVCs), are a rare congenital heart disease in dogs. Surgical correction is essential when clinical signs or significant hemodynamic changes are present. We aimed to report on the successful surgical correction of an SVASD with PAPVCs, using a computed tomography (CT)-based customized 3D cardiac model. A 10-month-old male poodle was referred for corrective surgery for an ASD. Echocardiography confirmed a hemodynamically significant left-to-right shunting flow through an interatrial septal defect and severe right-sided heart volume overload. For a comprehensive diagnosis, a CT scan was performed, which confirmed an SVASD with PAPVCs. A customized 3D cardiac model was used for preoperative decision-making and surgical rehearsal. The defect was repaired using an autologous pericardial patch under a cardiopulmonary bypass (CPB). Temporary pacing was applied for sinus bradycardia and third-degree atrioventricular block. The patient recovered from the anesthesia without further complications. The pacemaker was removed during hospitalization and the patient was discharged without complications 2 weeks post-surgery. At the three-month follow-up, there was no shunting flow in the interatrial septum and the right-sided volume overload had been resolved. The cardiac medications were discontinued, and there were no complications. This report indicates the validity of surgical correction under CPB for an SVASD with PAPVCs, and the advantages of utilizing a CT-based 3D cardiac model for preoperative planning to increase the surgical success rate.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Animals (Basel) Año: 2024 Tipo del documento: Article Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Animals (Basel) Año: 2024 Tipo del documento: Article Pais de publicación: Suiza