Your browser doesn't support javascript.
loading
Safety and efficacy of implantable phakic contact lens versus implantable collamer lens in myopia correction.
Amer, Ibrahim; Ziada, Hossameldin A; Elgazzar, Akram Fekry; Abdella, Walid Shaban; Abdelgbar, Ahmed Abdelaleem; Goda, Islam; Amer, Ramy Saleh; Abdel-Rahman Osman, Hamdy Osman; Mohamed, Sanaa Ahmed; Mansour, Mona N; Alsadawy Hassan, Mohamed; El Gabbar, Abdel Ghany Ali; Hamed, Mohamed Atito.
Afiliación
  • Amer I; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Assiut, Egypt.
  • Ziada HA; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Assiut, Egypt.
  • Elgazzar AF; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Damietta, Egypt.
  • Abdella WS; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Damietta, Egypt.
  • Abdelgbar AA; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Assiut, Egypt.
  • Goda I; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt.
  • Amer RS; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Damietta, Egypt.
  • Abdel-Rahman Osman HO; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Assiut, Egypt.
  • Mohamed SA; Department of Ophthalmology, Faculty of Medicine for Girls, Al-Azhar University, Cairo, Egypt.
  • Mansour MN; Department of Ophthalmology, Faculty of Medicine for Girls, Al-Azhar University, Cairo, Egypt.
  • Alsadawy Hassan M; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt.
  • El Gabbar AGA; Department of Ophthalmology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt.
  • Hamed MA; Department of Ophthalmology, Faculty of Medicine, Luxor University, Luxor, Egypt.
Article en En | MEDLINE | ID: mdl-38601054
ABSTRACT

Background:

Phakic intraocular lenses (pIOLs) have proven to be excellent substitutes for excimer laser keratorefractive surgery in certain situations. We aimed to assess the efficacy and safety of two pIOLs, the implantable collamer lens (ICL V4c) versus the implantable phakic contact lens (IPCL V2), for myopic correction.

Methods:

In this prospective randomized clinical trial, we allocated eligible eyes with myopia > - 6 diopters into IPCL or ICL implantation groups, each including 100 eyes of 100 individuals. Preoperative and postoperative assessments at 3, 6, and 12 months included measurements of the spherical equivalent (SE), uncorrected distance visual acuity (UCDVA), best-corrected distance visual acuity (BCDVA), intraocular pressure (IOP), maximum keratometry (K1), minimum keratometry (K2), mean keratometry (Kmean), anterior chamber depth (ACD), anterior chamber angle (ACA), and endothelial cell density (ECD).

Results:

The groups had comparable demographic characteristics and baseline visual and anatomical values (all P > 0.05). The UCDVA, BCDVA, and SE of the two groups were comparable at baseline and at all postoperative follow-up examinations (all P > 0.05). Both groups experienced significant improvements in UCDVA, BCDVA, and SE at three months postoperatively (all P = 0.001), and measurements remained stable for up to 12 months. Keratometry readings were comparable between the groups over the follow-up period and remained unchanged at all visits (all P > 0.05). The ACA in the ICL group was significantly decreased at three months postoperatively (P = 0.001) and then widened significantly at 6 and 12 months (both P = 0.001). In the IPCL group, the postoperative ACA was significantly decreased at three months (P = 0.001) and was comparable to that in the ICL group (P > 0.01). However, at the 6- and 12-month postoperative visits, the ACA was significantly narrower in the IPCL group than in the ICL group (both P = 0.001). The ACD in both groups was decreased at three months postoperatively (both P = 0.001) and remained stable until the end of the study. The ECD remained comparable between the groups at all postoperative visits (all P > 0.05). We did not observe a significant ECD reduction in either group at any postoperative follow-up visit (all P > 0.05). We encountered no serious complications in either group.

Conclusions:

ICL and IPCL had comparable safety and efficacy outcomes in terms of anterior chamber morphometrics, visual and refractive results, and corneal parameters. Further multicenter randomized clinical trials with longer follow-up periods, larger sample sizes, and measurement of additional anterior chamber and corneal morphometrics, vault, and other vision parameters are needed to verify these findings.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Med Hypothesis Discov Innov Ophthalmol Año: 2023 Tipo del documento: Article País de afiliación: Egipto Pais de publicación: Estados Unidos