Your browser doesn't support javascript.
loading
Greenness-sustainability metrics for assessment smart-chemometric spectrophotometric strategy for evaluation of the combination of six gastric proton-pump inhibitors with two selected impurities.
Amin, Khanda F M.
Afiliación
  • Amin KFM; Chemistry Department, College of Science, University of Sulaimani, Sulaymaniyah, Iraq.
MethodsX ; 12: 102670, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38577411
ABSTRACT
Green analytical approaches are employed for the determination of active pharmaceutical ingredients, in conjunction with their impurities. Smart chemometric spectrophotometric techniques, including orthogonal partial least square (OPLS), variable selection such as genetic algorithm (GA-OPLS), and interval selection (i-OPLS), were utilized. These chemometric models were implemented for assessing six proton-pump inhibitors Omeprazole, Esomeprazole, Lansoprazole, Pantoprazole, Rabeprazole, and Dexlansoprazole along with two selected official impurities, namely 4-Desmethoxy omeprazole impurity and Rabeprazole-impurity B. Experimental design was implemented to separate impurities, in the process of multivariate calibration, a five-level eight-factor calibration design consisting of 25 samples was selected. This design was deliberately selected to guarantee that the components were mutually orthogonal to assess the model's performance and reliability, a separate validation set of 15 samples was constructed. The best-performing of the proposed techniques were identified by considering the least favorable values of the Correlation Coefficient (R ≥ 0.9995), the Root Mean Square Error of Prediction (RMSEP) values between (0.0102-0.5622), and the Relative Error of Prediction (REP) values between (0.2961-1.1917). The proposed and reported methods' greenness-sustainability was quantitatively evaluated, and a comparative study of the greenness profile was established through a spider chart, the National Environmental Method Index tool, advanced and modified NEMI along with the Hexagon tool, and the whiteness qualities of the presented approaches were assessed by implementing the recently adopted Red-Green-Blue paradigm and White Analytical Chemistry tool. These approaches are well-suited for use in quality control laboratories due to their observed acceptance, long-term sustainability, simplicity, and affordability.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: MethodsX Año: 2024 Tipo del documento: Article País de afiliación: Irak Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: MethodsX Año: 2024 Tipo del documento: Article País de afiliación: Irak Pais de publicación: Países Bajos