Your browser doesn't support javascript.
loading
Experimental study on the an-isotropic critical current of REBCO tape.
Ma, Hongjun; Zhang, Jingfeng; Zhang, Shuqing; Zhang, Xintao; Liu, Huajun; Liu, Fang; Shi, Yi; Jin, Huan.
Afiliación
  • Ma H; Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People's Republic of China.
  • Zhang J; Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People's Republic of China.
  • Zhang S; Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People's Republic of China.
  • Zhang X; Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People's Republic of China.
  • Liu H; Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People's Republic of China.
  • Liu F; Hefei International Applied Superconductivity Center, Hefei 230071, People's Republic of China.
  • Shi Y; Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People's Republic of China.
  • Jin H; Institute of Energy, Hefei Comprehensive National Science Center, Hefei 230051, People's Republic of China.
Rev Sci Instrum ; 95(3)2024 Mar 01.
Article en En | MEDLINE | ID: mdl-38441429
ABSTRACT
Superconducting magnets are widely used in nuclear fusion reactors, high-energy particle accelerators, steady-state high magnetic fields, etc. Higher magnetic fields and higher operating temperatures are two application trends. High temperature superconducting (HTS) materials are the only choice for high temperature and high field magnets in the future. The first- and second-generation HTS materials have a typical tape structure; their critical performance is magnetic field angle and temperature dependent. A new test facility is developed for an experimental study on the an-isotropic critical current. The field angle can be changed from 0° to 360° with a resolution of 1°. The rotation deviation angle is measured to be 0.2° when the upper part rotates 90°. The temperature can be changed from 4.2 to 80 K. The temperature errors are ±50, ±80, and ±135 mK for 4.2-20, 20-40, and 40-80 K, respectively. The angle dependence of critical current (Ic) of the tested rare-earth barium copper oxide tape within 0°-30° is strong. From 30° to 90°, the sample Ic almost does not change with the magnetic field angle. The implementation of the project will not only promote the structural optimization of HTS tapes but also promote the miniaturization and economical application of HTS magnets.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2024 Tipo del documento: Article Pais de publicación: Estados Unidos