Your browser doesn't support javascript.
loading
The relationship between preoperative blood pressure during anesthetic examinations and pre-intubation blood pressure.
Koibuchi, Ikuya; Kadoi, Yuji; Asou, Chizu; Saito, Shigeru.
Afiliación
  • Koibuchi I; Department of Anesthesiology, Gunma University Graduate School of Medicine, 3-39-22 Showa-Machi, Maebashi, Gunma, 371-8511, Japan. carpgo0919@gmail.com.
  • Kadoi Y; Division of Operation Room, Gunma University Hospital, 3-39-15 Showa-Machi, Maebashi, Gunma, 371-8511, Japan.
  • Asou C; Department of Anesthesiology, Gunma University Graduate School of Medicine, 3-39-22 Showa-Machi, Maebashi, Gunma, 371-8511, Japan.
  • Saito S; Department of Anesthesiology, Gunma University Graduate School of Medicine, 3-39-22 Showa-Machi, Maebashi, Gunma, 371-8511, Japan.
BMC Anesthesiol ; 24(1): 89, 2024 Mar 02.
Article en En | MEDLINE | ID: mdl-38431570
ABSTRACT

BACKGROUND:

There have been few reports showing the relationship between blood pressure (BP) measured at clinics preoperatively and BP measured before anesthetic intubation/induction. The purpose of this study was to examine the relationship between BP measured at different times and settings preoperatively and BP measured before intubation/induction.

METHODS:

A total of 182 patients who underwent general anesthesia between March 2021 and April 2022 in a university hospital were examined. In addition to self-reported BP asked on an anesthetic examination sheet completed by each patient, BPs were measured three times, before, during, and after preoperative examination by the anesthesiologist. The derived parameter was compared with BP measured before intubation at the time of general anesthesia induction.

RESULTS:

The systolic BP in the intra-examination period had the most significant correlation with pre-intubation systolic BP (r = 0.5230, p < 0.0001, 95% CI = 0.4050 to 0.6238). On Bland-Altman analysis, the intra-examination systolic BP seemed to be similar and showed better agreement with pre-intubation systolic BP than other measured BPs, with a mean bias of 2.2 mmHg and the narrowest 95% limits of agreement (-33.7 to + 38.1 mmHg).

CONCLUSIONS:

The preoperative systolic BP value measured during the examination by the anesthesiologist was found to be closely related to pre-intubation systolic BP measured in the operating room. Higher BP during the preoperative examination may be a result of anxiety-induced stress or white-coat hypertension. Measuring BP during the anesthesiologist's examination may be useful for predicting hypertension in the pre-intubation period.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hipertensión / Anestésicos Límite: Humans Idioma: En Revista: BMC Anesthesiol Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Hipertensión / Anestésicos Límite: Humans Idioma: En Revista: BMC Anesthesiol Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Reino Unido