Your browser doesn't support javascript.
loading
Multispectral singlet oxygen luminescent dosimetry (MSOLD) for Photofrin-mediated Photodynamic Therapy.
Yang, Weibing; Rastogi, Vivek; Sun, Hongjing; Sharma, Dvij; Wilson, Brian C; Hadfield, Robert H; Zhu, Timothy C.
Afiliación
  • Yang W; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104.
  • Rastogi V; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104.
  • Sun H; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104.
  • Sharma D; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104.
  • Wilson BC; Department of Medical Biophysics, University of Toronto, Toronto, Canada.
  • Hadfield RH; Department of Physics, University of Glasgow, Glasgow, UK.
  • Zhu TC; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA 19104.
Article en En | MEDLINE | ID: mdl-38419618
ABSTRACT
Direct detection of singlet-state oxygen ([1O2]) constitutes the holy grail dosimetric method for type II PDT, a goal that can be quantified using multispectral singlet oxygen dosimetry (MSOLD). However, the short lifetime and extremely weak nature of the singlet oxygen signal produced has given rise to a need to improve MSOLD signal-to-noise ratio. This study examines methods for optimizing MSOLD signal acquisition, specifically employing an orthogonal arrangement between detection and PDT treatment light, consisting of two fiber optics - connected to a 632-nm laser and an InGaAs detector respectively. Light collected by the InGaAs detector is then passed through a filter wheel, where spectral emission measurements are taken at 1200 nm, 1240 nm, 1250 nm, 1270 nm, and 1300 nm. The data, after fitting to the fluorescence background and a gaussian-fit for the singlet oxygen peak, is established for the background-subtracted singlet oxygen emission signal. The MSOLD signal is then compared with the singlet oxygen explicit dosimetry (SOED) results, based on direct measurements of in-vivo light fluence (rate), in-vivo Photofrin concentration, and tissue oxygenation concentration. This study focuses on validating the sensitivity and minimum detectability of MSOLD signal in various in-vitro conditions. Finally, the MSOLD device will be tested in Photofrin-mediated PDT for mice bearing Radiation-Induced Fibrosarcoma (RIF) tumors.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Proc SPIE Int Soc Opt Eng Año: 2023 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Proc SPIE Int Soc Opt Eng Año: 2023 Tipo del documento: Article Pais de publicación: Estados Unidos