Your browser doesn't support javascript.
loading
Comparison of osteolysis around 3 different cement restrictors in total hip arthroplasty.
Prins, Wybren; Cornelissen, Maarten P; Goudriaan, W Alexander; Edens, Mireille A; Amaya, Jeremy; Zollinger, Paul E; Verheyen, Cees C P M; Ettema, Harmen B.
Afiliación
  • Prins W; Department of Orthopaedic Surgery and Traumatology, Isala, Zwolle, Overijssel, The Netherlands.
  • Cornelissen MP; Department of Orthopaedic Surgery and Traumatology, Isala, Zwolle, Overijssel, The Netherlands.
  • Goudriaan WA; Department of Orthopaedic Surgery and Traumatology, Isala, Zwolle, Overijssel, The Netherlands.
  • Edens MA; Department Innovation and Science, Isala, Zwolle, Overijssel, The Netherlands.
  • Amaya J; Department of Orthopaedic Surgery and Traumatology, Dijklander Hospital, Hoorn and Purmerend, Noord-Holland, The Netherlands.
  • Zollinger PE; Department of Orthopaedic Surgery and Traumatology, Ziekenhuis Rivierenland, Tiel, Gelderland, The Netherlands.
  • Verheyen CCPM; Department of Orthopaedic Surgery and Traumatology, Isala, Zwolle, Overijssel, The Netherlands.
  • Ettema HB; Department of Orthopaedic Surgery and Traumatology, Isala, Zwolle, Overijssel, The Netherlands.
Hip Int ; 34(2): 221-227, 2024 Mar.
Article en En | MEDLINE | ID: mdl-38414223
ABSTRACT
BACKGROUND AND

AIM:

Several studies reported osteolysis around polyethylene glycol/polybutylene terephthalate (PEG/PBT) based femoral cement restrictors. Our goal was to evaluate and compare osteolysis around 3 different plug designs the slow biodegradable PEG/PBT cement restrictor; the fast biodegradable gelatin cement restrictor; and the non-biodegradable polyethylene plug. PATIENTS AND

METHODS:

In a retrospective multicentre cohort study chart data were extracted of patients who received a total hip arthroplasty between 2008 and 2012. A total of 961 hips were included. Cortical ratio between inner and outer cortices at the centre of the plug was measured on routine postoperative follow-up moments. Median follow up of all 3 hospitals was 3.5 years (1.4-7.3). The primary outcome was evidence of osteolysis (i.e. the difference in cortical ratio [CR]) on anteroposterior (AP) radiographs at final follow-up.

RESULTS:

Progressive osteolysis was found around the PEG/PBT cement restrictor represented by a significantly increasing cortical ratio (ΔCR 0.067 (95% CI, 0.063-0.071). Distance from tip prosthesis to plug and size of the plug were found to be independent factors in predicting increased cortical ratio.

CONCLUSIONS:

Our multicentre cohort shows increase of cortical ratio around the PEG/PBT cement restrictor which progresses over time. Physicians should be aware of this fact and are advised to intensify follow-up of patients who received this cement restrictor.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteólisis / Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Límite: Humans Idioma: En Revista: Hip Int Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Osteólisis / Artroplastia de Reemplazo de Cadera / Prótesis de Cadera Límite: Humans Idioma: En Revista: Hip Int Año: 2024 Tipo del documento: Article País de afiliación: Países Bajos Pais de publicación: Estados Unidos