Your browser doesn't support javascript.
loading
Neck circumference is a highly reliable anthropometric measure in older adults requiring long-term care.
Sato, Ryo; Sawaya, Yohei; Ishizaka, Masahiro; Yin, Lu; Shiba, Takahiro; Hirose, Tamaki; Urano, Tomohiko.
Afiliación
  • Sato R; Department of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
  • Sawaya Y; Department of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
  • Ishizaka M; Department of Physical Therapy, School of Health Sciences, International University of Health and Welfare, Otawara, Tochigi, Japan.
  • Yin L; Department of Physical Therapy, School of Health Sciences, International University of Health and Welfare, Otawara, Tochigi, Japan.
  • Shiba T; Department of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
  • Hirose T; Department of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
  • Urano T; Department of Day Rehabilitation, Care Facility for the Elderly "Maronie-en", Nishinasuno General Home Care Center, Nasushiobara, Tochigi, Japan.
PeerJ ; 12: e16816, 2024.
Article en En | MEDLINE | ID: mdl-38313007
ABSTRACT
The reliability of neck circumference measurement as an assessment tool for older adults requiring long-term care remains unknown. This study aimed to evaluate the reliability of neck circumference measurement in older adults requiring long-term care, and the effect of edema on measurement error. Two physical therapists measured the neck circumference. Intraclass correlation coefficient (ICC) and Bland-Altman analyses were performed to examine the reliability of neck circumference measurement. Correlation analysis was used to evaluate the relationship between edema values (extracellular water/total body water) and neck circumference measurement difference. For inter-rater reliability of neck circumference measurement, the overall ICC (2,1) was 0.98. The upper and lower limits of the difference between examiners ranged from -0.9 to 1.2 cm. There was no association between edema values and neck circumference measurement error. Thus, measurement of the neck circumference in older adults requiring long-term care is a reliable assessment tool, with a low error rate, even in older adults with edema.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cuidados a Largo Plazo / Cuello Tipo de estudio: Diagnostic_studies Límite: Aged / Humans Idioma: En Revista: PeerJ Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Cuidados a Largo Plazo / Cuello Tipo de estudio: Diagnostic_studies Límite: Aged / Humans Idioma: En Revista: PeerJ Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos