Your browser doesn't support javascript.
loading
Protein-Aided Synthesis of Copper-Integrated Polyaniline Nanocomposite Encapsulated with Reduced Graphene Oxide for Highly Sensitive Electrochemical Detection of Dimetridazole in Real Samples.
Behera, Kartik; Mutharani, Bhuvanenthiran; Chang, Yen-Hsiang; Kumari, Monika; Chiu, Fang-Chyou.
Afiliación
  • Behera K; Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Mutharani B; Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan 333, Taiwan.
  • Chang YH; Department of General Dentistry, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan.
  • Kumari M; Institute of Cellular and Organismic Biology, Academia Sinica, Taipei 115, Taiwan.
  • Chiu FC; Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan 333, Taiwan.
Polymers (Basel) ; 16(1)2024 Jan 04.
Article en En | MEDLINE | ID: mdl-38201827
ABSTRACT
Dimetridazole (DMZ) is a derivative of nitroimidazole and is a veterinary drug used as an antibiotic to treat bacterial or protozoal infections in poultry. The residues of DMZ cause harmful side effects in human beings. Thus, we have constructed a superior electrocatalyst for DMZ detection. A copper (Cu)-integrated poly(aniline) (PANI) electrocatalyst (PANI-Cu@BSA) was prepared by using a one-step method of biomimetic mineralization and polymerization using bovine serum albumin (BSA) as a stabilizer. Then, the synthesized PANI-Cu@BSA was encapsulated with reduced graphene oxide (rGO) using an ultrasonication method. The PANI-Cu@BSA/rGO nanocomposite had superior water dispersibility, high electrical conductivity, and nanoscale particles. Moreover, a PANI-Cu@BSA/rGO nanocomposite-modified, screen-printed carbon electrode was used for the sensitive electrochemical detection of DMZ. In phosphate buffer solution, the PANI-Cu@BSA/rGO/SPCE displayed a current intensity greater than PANI-Cu@BSA/SPCE, rGO/SPCE, and bare SPCE. This is because PANI-Cu@BSA combined with rGO increases fast electron transfer between the electrode and analyte, and this synergy results in analyte-electrode junctions with extraordinary conductivity and active surface areas. PANI-Cu@BSA/rGO/SPCE had a low detection limit, a high sensitivity, and a linear range of 1.78 nM, 5.96 µA µM-1 cm-2, and 0.79 to 2057 µM, respectively. The selective examination of DMZ was achieved with interfering molecules, and the PANI-Cu@BSA/rGO/SPCE showed excellent selectivity, stability, repeatability, and practicability.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Polymers (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Taiwán Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Polymers (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Taiwán Pais de publicación: Suiza