Your browser doesn't support javascript.
loading
CT and MR imaging of radiation hepatitis.
J Comput Assist Tomogr ; 11(2): 264-8, 1987.
Article en En | MEDLINE | ID: mdl-3819125
The authors describe two cases of radiation hepatitis evaluated by magnetic resonance imaging and CT with CT angiography (CTA) additionally performed in one patient. On CT the radiation hepatitis appeared as sharply demarcated region of lower attenuation than the adjacent normal liver. The region of radiation hepatitis demonstrated decreased perfusion in the portal venous phase of CTA, and 4 min delayed images following CTA showed increased density or relative increased accumulation of contrast. Magnetic resonance in both cases showed that the area of low density on CT had high signal on the T2-weighted image and had increased water content as determined by proton spectroscopic imaging method.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Traumatismos por Radiación / Espectroscopía de Resonancia Magnética / Tomografía Computarizada por Rayos X / Hepatitis Tipo de estudio: Etiology_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Comput Assist Tomogr Año: 1987 Tipo del documento: Article Pais de publicación: Estados Unidos
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Traumatismos por Radiación / Espectroscopía de Resonancia Magnética / Tomografía Computarizada por Rayos X / Hepatitis Tipo de estudio: Etiology_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Comput Assist Tomogr Año: 1987 Tipo del documento: Article Pais de publicación: Estados Unidos