Your browser doesn't support javascript.
loading
Chronological Changes in Sagittal Femoral Bowing after Primary Cementless Total Hip Arthroplasty: A Comparative 3D CT Study.
Pardo, Francesco; La Mattina, Antonino Amedeo; Diquattro, Emanuele; Lucchini, Stefano; Viceconti, Marco; Minerba, Andrea; Castagnini, Francesco; Traina, Francesco.
Afiliación
  • Pardo F; Orthopedics-Traumatology and Prosthetic Surgery and Hip and Knee Revision, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
  • La Mattina AA; Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
  • Diquattro E; Department of Industrial Engineering, Alma Mater Studiorum-University of Bologna (IT), 40136 Bologna, Italy.
  • Lucchini S; Orthopedics-Traumatology and Prosthetic Surgery and Hip and Knee Revision, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
  • Viceconti M; Orthopedics-Traumatology and Prosthetic Surgery and Hip and Knee Revision, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
  • Minerba A; Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
  • Castagnini F; Department of Industrial Engineering, Alma Mater Studiorum-University of Bologna (IT), 40136 Bologna, Italy.
  • Traina F; Orthopedics-Traumatology and Prosthetic Surgery and Hip and Knee Revision, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy.
J Pers Med ; 13(12)2023 Dec 13.
Article en En | MEDLINE | ID: mdl-38138931
ABSTRACT
Little is known about dynamic changes of femoral anatomy after total hip arthroplasty (THA), in particular about sagittal femoral bowing (SFB). A 3D CT study was designed to evaluate the chronological changes of SFB after cementless femoral stem implantation for primary THA. Ten patients who underwent unilateral primary THA with a cementless femoral stem, with 2 consecutive CT scans (extending from the fourth lumbar vertebra to the tibial plateaus), performed before THA and at least 3 years after THA, were enrolled. The 3D models of femurs were created using image segmentation software. Using the two CT scans, SFB values of the proximal and middle thirds were calculated on the replaced and untreated sides by two different observers. Eight anatomical stems and two conical stems were involved. The post-operative CT was performed at an average follow-up of 6.5 years after THA (range 3-12.5). The measurements performed by the two observers did not differ in the proximal and middle regions. A significant difference between the pre-operative and post-operative SFB compared to the untreated side was found in the proximal femur segment (p = 0.004). Use of a cementless stem in THA induced chronological changes in SFB of the proximal femur, after a minimum timespan of 3 years.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Pers Med Año: 2023 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: J Pers Med Año: 2023 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Suiza