Your browser doesn't support javascript.
loading
Rapid and high throughput assessment of cellular immunity against SARS-CoV-2 based on the ex vivo activation of genes in leukocyte assay with whole blood.
Saito, Taro; Couzinet, Arnaud; Murakami, Taku; Shimomura, Manami; Suzuki, Toshihiro; Katayama, Yuki; Nakatsura, Tetsuya.
Afiliación
  • Saito T; Minaris Medical Co., Ltd, Nagaizumi, Shizuoka, 411-0932, Japan.
  • Couzinet A; Division of Cancer Immunotherapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, Kashiwa, Chiba, 277-8577, Japan.
  • Murakami T; Resonac America, Inc., San Jose, CA, 95131, USA.
  • Shimomura M; Division of Cancer Immunotherapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, Kashiwa, Chiba, 277-8577, Japan.
  • Suzuki T; Division of Cancer Immunotherapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, Kashiwa, Chiba, 277-8577, Japan.
  • Katayama Y; Minaris Medical Co., Ltd, Nagaizumi, Shizuoka, 411-0932, Japan; Resonac Corporation, Minato, Tokyo, 105-7325, Japan. Electronic address: katayama.yuki.xicsp@minarismedical.com.
  • Nakatsura T; Division of Cancer Immunotherapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, Kashiwa, Chiba, 277-8577, Japan.
Biochem Biophys Res Commun ; 694: 149398, 2024 01 29.
Article en En | MEDLINE | ID: mdl-38134475
ABSTRACT
During the novel coronavirus outbreak and vaccine development, antibody production garnered major focus as the primary immunogenic response. However, cellular immunity's recent demonstration of comparable or greater significance in controlling infection demands the re-evaluation of the importance of T-cell immunity in SARS-CoV-2 infection. Here, we developed a novel assay, the ex vivo activation of genes in leukocytes (EAGL), which employs short-term whole blood stimulation with the LeukoComplete™ system, to measure ex vivo SARS-CoV-2-specific T cell responses (cellular immunity). This assay measures upregulated mRNA expression related to leukocyte activation 4 h after antigen stimulation. LeukoComplete™ system uses whole blood samples, eliminating the need for pretreatment before analysis. Furthermore, this system's high reproducibility is ensured through a series of operations from mRNA extraction to cDNA synthesis on a 96-well plate. In the performance evaluation using fresh blood from previously SARS-CoV-2-infected and COVID-19-vaccinated individuals, the EAGL assay had a comparable sensitivity and specificity to the ELISpot assay (EAGL 1.000/1.000; ELISpot 0.900/0.973). As a simple, high-throughput assay, the EAGL assay is also a quantitative test that is useful in studies with large sample numbers, such as monitoring new vaccine efficacies against novel coronaviruses or epidemiologic studies that require cellular immune testing during viral infection.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: SARS-CoV-2 / COVID-19 Límite: Humans Idioma: En Revista: Biochem Biophys Res Commun Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: SARS-CoV-2 / COVID-19 Límite: Humans Idioma: En Revista: Biochem Biophys Res Commun Año: 2024 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Estados Unidos