Digitally designed and manufactured sectional custom tray for a patient with microstomia: A case report.
J Prosthodont
; 33(4): 307-312, 2024 Apr.
Article
en En
| MEDLINE
| ID: mdl-37927117
Microstomia presents a challenge for the patient and dental provider. This report describes a partial digital workflow for the fabrication of a mandibular complete denture for a patient with microstomia. Computer-aided design and computer-aided manufacturing technology was utilized to 3D print a sectional custom tray with a unique design. The sectional custom tray was used to make a conventional border molded impression of the edentulous arch to fabricate a flexible complete mandibular denture for a 58-year-old female patient with scleroderma and microstomia. This treatment resulted in a successful prosthetic outcome and high patient satisfaction.
Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Boca Edéntula
/
Microstomía
Límite:
Female
/
Humans
/
Middle aged
Idioma:
En
Revista:
J Prosthodont
Asunto de la revista:
ODONTOLOGIA
Año:
2024
Tipo del documento:
Article
País de afiliación:
Estados Unidos
Pais de publicación:
Estados Unidos