Your browser doesn't support javascript.
loading
A novel portable immuno-device for the recognition of lymphatic vessel endothelial hyaluronan receptor-1 biomarker using GQD-AgNPrs conductive ink stabilized on the surface of cellulose.
Mobed, Ahmad; Kohansal, Fereshteh; Dolati, Sanam; Hasanzadeh, Mohammad.
Afiliación
  • Mobed A; Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences Tabriz 51664 Iran hasanzadehm@tbzmed.ac.ir.
  • Kohansal F; Aging Research Institute, Faculty of Medicine, Tabriz University of Medical Sciences Iran.
  • Dolati S; Physical Medicine and Rehabilitation Research Center, Aging Research Institute, Faculty of Medicine, Tabriz University of Medical Sciences Iran sanam.dolati@gmail.com.
  • Hasanzadeh M; Nutrition Research Center, Tabriz University of Medical Sciences Tabriz Iran.
RSC Adv ; 13(44): 30925-30936, 2023 Oct 18.
Article en En | MEDLINE | ID: mdl-37876653
Lymphatic vessel endothelium expresses various lymphatic marker molecules. LYVE-1, the lymphatic vessel endothelial hyaluronan (HA) receptor, a 322-residue protein belonging to the integral membrane glycoproteins which is found on lymph vessel wall and is completely absent from blood vessels. LYVE-1 is very effective in the passage of lymphocytes and tumor cells into the lymphatics. As regards cancer metastasis, in vitro studies indicate LYVE-1 to be involved in tumor cell adhesion. Researches show that, in neoplastic tissue, LYVE-1 is limited to the lymphovascular and could well be proper for studies of tumor lymphangiogenesis. So, the monitoring of LYVE-1 level in human biofluids has provided a valuable approach for research into tumor lymphangiogenesis. For the first time, an innovative paper-based electrochemical immune-platform was developed for recognition of LYVE-1. For this purpose, graphene quantum dots decorated silver nanoparticles nano-ink was synthesized and designed directly by writing pen-on paper technology on the surface of photographic paper. This nano-ink has a great surface area for biomarker immobilization. The prepared paper-based biosensor was so small and cheap and also has high stability and sensitivity. For the first time, biotinylated antibody of biomarker (LYVE-1) was immobilized on the surface of working electrode and utilized for the monitoring of specific antigen by simple immune-assay strategy. The designed biosensor showed two separated linear ranges in the range of 20-320 pg ml-1 and 0.625-10 pg ml-1, with the acceptable limit of detection (LOD) of 0.312 pg ml-1. Additionally, engineered immunosensor revealed excellent selectivity that promises its use in complex biological samples and assistance for biomarker-related disease screening in clinical studies.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: RSC Adv Año: 2023 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: RSC Adv Año: 2023 Tipo del documento: Article Pais de publicación: Reino Unido