Your browser doesn't support javascript.
loading
Accuracy of a Glycerol Dehydrogenase Assay for Ethylene Glycol Detection.
Filip, Ari B; Farnsworth, Christopher W; Mullins, Michael E; Crews, Bridgit O; Kraut, Jeffrey A.
Afiliación
  • Filip AB; Arkansas Poison and Drug Information Center, University of Arkansas for Medical Sciences College of Pharmacy, Little Rock, AR, USA. abfilip@uams.edu.
  • Farnsworth CW; Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, MO, USA.
  • Mullins ME; Department of Emergency Medicine, Washington University School of Medicine, St. Louis, MO, USA.
  • Crews BO; Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, MO, USA.
  • Kraut JA; Medical and Research Services, VA Greater Los Angeles Healthcare System, Los Angeles, CA; UCLA Membrane Biology Laboratory, Division of Nephrology, David Geffen School of Medicine, UCLA, Los Angeles, CA, USA.
J Med Toxicol ; 19(4): 362-367, 2023 10.
Article en En | MEDLINE | ID: mdl-37695470
INTRODUCTION: Ethylene glycol (EG) is a frequently considered toxicant in poisoned patients. Definitive diagnosis relies on gas chromatography (GC), but this is unavailable at most hospitals. A glycerol dehydrogenase (GDH)-based assay rapidly detects EG. A rapid turnaround time and wide availability of necessary instrumentation suggest this method could facilitate the rapid detection of EG. METHODS: This is a prospective, observational analysis of banked, remnant serum samples submitted to the laboratory of a large, multi-hospital healthcare system. Samples were submitted over a 12-month period for the explicit purpose of testing for suspected EG ingestion. All samples underwent GC and the GDH-based assay. RESULTS: Of the 118 analyzed samples, 88 had no EG detected by GC, and 30 were "positive." At the manufacturer's threshold of 6 mg/dL EG, there was 100% (95%CI; 88.7-100) positive percent agreement (PPA) and 98% (92.1-99.6) negative percent agreement (NPA). Adjusted to a threshold of 9 mg/dL, both the PPA and NPA were 100%. Deming regression of the observed concentrations revealed a slope of 1.16 (1.01 to 1.32) and intercept of -5.3 (-8.9 to -1.7). CONCLUSIONS: The GDH assay provides a sensitive and specific method for the detection and quantification of EG that is comparable to a GC-based method. More widespread use of this rapid, inexpensive assay could improve the care of patients with suspected toxic alcohol exposure. Further study is needed to evaluate the test performance in real-time patient treatment decisions.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Deshidrogenasas del Alcohol de Azúcar / Sustancias Peligrosas Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Med Toxicol Asunto de la revista: TOXICOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Deshidrogenasas del Alcohol de Azúcar / Sustancias Peligrosas Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Humans Idioma: En Revista: J Med Toxicol Asunto de la revista: TOXICOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos