Your browser doesn't support javascript.
loading
Fine-needle aspiration biopsy of the thyroid gland: results of a five-year experience and discussion of its clinical limitations.
J Otolaryngol ; 15(3): 161-5, 1986 Jun.
Article en En | MEDLINE | ID: mdl-3755182
The results of a five-year experience with fine-needle thyroid aspiration cytology are reported to assess the value, accuracy and limitations of this biopsy procedure. The cytologic diagnoses on 1,465 thyroid aspirates are listed, and correlation of cytology with histology on 207 cases undergoing surgery is reported. The incidence of malignancy among the atypical and malignant cytology aspirates with histologic confirmed diagnosis was 65% (28/43) while a false negative rate of 11.5% (15/131) was found. Fine-needle aspiration biopsy is a safe and useful procedure with an acceptable accuracy rate that complements other investigations in the screening of patients for thyroid surgery.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glándula Tiroides / Neoplasias de la Tiroides Límite: Humans Idioma: En Revista: J Otolaryngol Año: 1986 Tipo del documento: Article Pais de publicación: Canadá
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glándula Tiroides / Neoplasias de la Tiroides Límite: Humans Idioma: En Revista: J Otolaryngol Año: 1986 Tipo del documento: Article Pais de publicación: Canadá