Dosimetric comparison of autocontouring techniques for online adaptive proton therapy.
Smolders, A; Choulilitsa, E; Czerska, K; Bizzocchi, N; Krcek, R; Lomax, A; Weber, D C; Albertini, F.
Afiliación
  • Smolders A; Paul Scherrer Institute, Center for Proton Therapy, Switzerland.
  • Choulilitsa E; Department of Physics, ETH Zurich, Switzerland.
  • Czerska K; Paul Scherrer Institute, Center for Proton Therapy, Switzerland.
  • Bizzocchi N; Department of Physics, ETH Zurich, Switzerland.
  • Krcek R; Paul Scherrer Institute, Center for Proton Therapy, Switzerland.
  • Lomax A; Paul Scherrer Institute, Center for Proton Therapy, Switzerland.
  • Weber DC; Paul Scherrer Institute, Center for Proton Therapy, Switzerland.
  • Albertini F; Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Switzerland.
Phys Med Biol ; 68(17)2023 08 11.
Article en En | MEDLINE | ID: mdl-37385266
Objective.Anatomical and daily set-up uncertainties impede high precision delivery of proton therapy. With online adaptation, the daily plan is reoptimized on an image taken shortly before the treatment, reducing these uncertainties and, hence, allowing a more accurate delivery. This reoptimization requires target and organs-at-risk (OAR) contours on the daily image, which need to be delineated automatically since manual contouring is too slow. Whereas multiple methods for autocontouring exist, none of them are fully accurate, which affects the daily dose. This work aims to quantify the magnitude of this dosimetric effect for four contouring techniques.Approach.Plans reoptimized on automatic contours are compared with plans reoptimized on manual contours. The methods include rigid and deformable registration (DIR), deep-learning based segmentation and patient-specific segmentation.Main results.It was found that independently of the contouring method, the dosimetric influence of usingautomaticOARcontoursis small (<5% prescribed dose in most cases), with DIR yielding the best results. Contrarily, the dosimetric effect of using theautomatic target contourwas larger (>5% prescribed dose in most cases), indicating that manual verification of that contour remains necessary. However, when compared to non-adaptive therapy, the dose differences caused by automatically contouring the target were small and target coverage was improved, especially for DIR.Significance.The results show that manual adjustment of OARs is rarely necessary and that several autocontouring techniques are directly usable. Contrarily, manual adjustment of the target is important. This allows prioritizing tasks during time-critical online adaptive proton therapy and therefore supports its further clinical implementation.