Your browser doesn't support javascript.
loading
[Status of the cardiovascular and respiratory systems during immunosorption]. / Sostoianie serdechno-sosudistoi i respiratornoi sistem pri provedenii immunosorbtsii.
Ter Arkh ; 58(4): 38-40, 1986.
Article en Ru | MEDLINE | ID: mdl-3715754
Blood was perfused through 2 series connected columns during immunosorption. The first column contained a mixture of immunosorbent and activated carbon, the second activated carbon only. In most patients the perfusion time was 40 min, and the volume of perfused blood 2000 ml. The procedure was performed under the conditions of operative control over the state of the cardiovascular and respiratory system using a monitor-computer system KOMPAS-01 in order to follow 5 hemodynamics values and 10 values of external respiration. A considerable effect of the procedure on the patients' hemodynamic patterns was revealed during hemosorption. These changes manifested themselves mainly in a decrease in stroke volume, cardiac output and changes in rate of the heart beat. External respiration values were more stable.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Respiración / Asma / Desensibilización Inmunológica / Hemoperfusión / Hemodinámica Límite: Adult / Female / Humans Idioma: Ru Revista: Ter Arkh Año: 1986 Tipo del documento: Article Pais de publicación: Rusia