Your browser doesn't support javascript.
loading
Comparison of 2D and autostereoscopic 3D visualization during mixed reality simulation.
Vörös, Viktor; De Smet, Jef; Ourak, Mouloud; Poliakov, Vladimir; Deprest, Jan; Kimpe, Tom; Vander Poorten, Emmanuel.
Afiliación
  • Vörös V; Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300, 3000, Leuven, Belgium. viktor.voros@kuleuven.be.
  • De Smet J; Healthcare Division, Barco NV, Beneluxpark 21, 8500, Kortrijk, Belgium. viktor.voros@kuleuven.be.
  • Ourak M; Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300, 3000, Leuven, Belgium.
  • Poliakov V; Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300, 3000, Leuven, Belgium.
  • Deprest J; Department of Mechanical Engineering, KU Leuven, Celestijnenlaan 300, 3000, Leuven, Belgium.
  • Kimpe T; Department of Obstetrics and Gynaecology, UZ Leuven, Herestraat 49, 3000, Leuven, Belgium.
  • Vander Poorten E; Healthcare Division, Barco NV, Beneluxpark 21, 8500, Kortrijk, Belgium.
Int J Comput Assist Radiol Surg ; 18(9): 1679-1686, 2023 Sep.
Article en En | MEDLINE | ID: mdl-36995512
PURPOSE: In general minimally invasive surgical procedures, surgeons are tied to 2D visualization, leading to the loss of depth perception. This can lead to large mental load for the surgeons and may be responsible for the long learning curve. To restore the sense of depth, this study investigated the use and benefits of an autostereoscopic (3D) display during a simulated laparoscopic task. METHODS: A mixed reality simulator was developed for comparing the performance of participants while using 2D and autostereoscopic 3D visualization. An electromagnetic sensor was mounted on a physical instrument, and its pose was mapped to the virtual instrument. The virtual scene was developed using Simulation Open Framework Architecture (SOFA). Finite element modeling was used to calculate interaction forces, which were then mapped to visual soft tissue deformation. RESULTS: Ten non-expert participants completed a virtual laparoscopic task, where the subjects were asked to contact eighteen target areas distributed on the surface of the vagina, both in 2D and 3D. Results showed an improvement with 3D vision in task completion time (-16%), total traveled distance (-25%) and errors made (-14%). There was no difference in the average contact forces between the vagina and the instrument. Only the difference in time and forces were shown to be statistically significant. CONCLUSION: Overall, autostereoscopic 3D showed superiority over conventional 2D visualization. The traveled trajectory increased in 2D as the instrument was retracted more between the targets to avoid contact. The 2D and 3D deformation upon contact seems not to contribute differently to force perception. However, the participants only had visual feedback, but no haptic feedback. Therefore, it could be interesting to include haptic feedback in a future study.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Laparoscopía / Realidad Aumentada Límite: Female / Humans Idioma: En Revista: Int J Comput Assist Radiol Surg Asunto de la revista: RADIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Laparoscopía / Realidad Aumentada Límite: Female / Humans Idioma: En Revista: Int J Comput Assist Radiol Surg Asunto de la revista: RADIOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Alemania