Your browser doesn't support javascript.
loading
Effects of polishing press-on force on surface roughness and gloss of CAD-CAM composites.
Yu, Peng; Luo, Hao; Yap, Adrian U; Tian, Fu-Cong; Wang, Xiao-Yan.
Afiliación
  • Yu P; Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology.
  • Luo H; Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology.
  • Yap AU; Department of Dentistry, Ng Teng Fong General Hospital.
  • Tian FC; Faculty of Dentistry, National University of Singapore.
  • Wang XY; National Dental Centre Singapore.
J Oral Sci ; 65(2): 131-135, 2023.
Article en En | MEDLINE | ID: mdl-36990758
PURPOSE: The aim of this study was to determine the effect of polishing press-on force on surface roughness and gloss of computer-aided design-computer-aided manufacturing (CAD-CAM) composites. METHODS: The materials evaluated included a CAD-CAM ceramic, a polymer-infiltrated ceramic, and three filler-based CAD-CAM composites. The CAD-CAM blocks were sectioned, embedded in self-cured resin, finished with abrasive papers and ultrasonically cleaned. Specimens were subsequently polished using the Sof-Lex disk system with 0.5, 1.0, 1.5, and 2.0 N press-on force by means of a custom-made apparatus. Contour arithmetic mean deviation (Ra) and gloss value (GU) data were acquired with a profilometer and glossmeter, respectively, and analyzed using ANOVA/Bonferroni post hoc test and Pearson's correlation (α = 0.05). Representative samples of the various materials at baseline and after each polishing step were examined under scanning electron microscope. RESULTS: Mean Ra and GU values ranged from 0.096 ± 0.004 µm to 0.295 ± 0.045 µm and 13.4 ± 1.9 to 67.6 ± 11.3 correspondingly for the various material-force combinations. Surface roughness and gloss were found to be press-on force and material dependent. A moderately strong and negative correlation (rs = -0.69) existed between Ra and GU values. CONCLUSION: For optimal smoothness and gloss, ceramic and polymer-infiltrated ceramic CAD-CAM materials must be polished with a 2.0 N force, while filler-based CAD-CAM composites should, in general, be polished using a 1.0 to 1.5 N force.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Resinas Compuestas / Pulido Dental Tipo de estudio: Evaluation_studies Límite: Humans Idioma: En Revista: J Oral Sci Asunto de la revista: ODONTOLOGIA Año: 2023 Tipo del documento: Article Pais de publicación: Japón

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Resinas Compuestas / Pulido Dental Tipo de estudio: Evaluation_studies Límite: Humans Idioma: En Revista: J Oral Sci Asunto de la revista: ODONTOLOGIA Año: 2023 Tipo del documento: Article Pais de publicación: Japón