Dynamic tumor-tracking stereotactic body radiotherapy with real-time monitoring of liver tumors using a gimbal-mounted linac: A multi-institutional phase II study.
Clin Transl Radiat Oncol
; 39: 100591, 2023 Mar.
Article
en En
| MEDLINE
| ID: mdl-36852258
4D, four-dimensional; CT, computed tomography; CTV, clinical target volume; DTT, dynamic tumor tracking; Dynamic tumor tracking; GTV, gross tumor volume; HCC, hepatocellular carcinoma; IR, infrared; LC, local control; Liver; Malignant neoplasms; Metastasis; OAR, organs at risk; OS, overall survival; PFS, progression-free survival; PTV, planning target volume; RFA, radiofrequency ablation; SBRT, stereotactic body radiotherapy; Stereotactic body radiotherapy; TV, target volume