Your browser doesn't support javascript.
loading
LC-QQQ-MS based intracellular quantification of bictegravir in peripheral blood mononuclear cells and plasma.
Jadav, Tarang; Rajput, Niraj; Sahu, Amit Kumar; Sengupta, Pinaki.
Afiliación
  • Jadav T; National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Opp. Airforce Station, Palaj, Gandhinagar, 382355, Gujarat, India.
  • Rajput N; National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Opp. Airforce Station, Palaj, Gandhinagar, 382355, Gujarat, India.
  • Sahu AK; National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Opp. Airforce Station, Palaj, Gandhinagar, 382355, Gujarat, India.
  • Sengupta P; National Institute of Pharmaceutical Education and Research-Ahmedabad (NIPER-A), An Institute of National Importance, Government of India, Department of Pharmaceuticals, Ministry of Chemicals and Fertilizers, Opp. Airforce Station, Palaj, Gandhinagar, 382355, Gujarat, India. Electronic address: psg7
Anal Biochem ; 667: 115084, 2023 04 15.
Article en En | MEDLINE | ID: mdl-36806669
Most antiretrovirals (ARVs) have intracellular therapeutic target sites and therefore, their plasma concentration may be misleading when relating to their efficacy or toxicity. A bioanalytical method for quantification of the ARV drug bictegravir (BTG) in its target site peripheral blood mononuclear cells (PBMCs) is not available till date. This is the first time to establish a sufficiently sensitive mass spectrometry-based bioanalytical method to quantify BTG in both rat PBMCs and plasma. The developed method was validated over the range of 1 ng/ml to 100 ng/ml and 0.005 ng-10ng/sample for plasma and PBMCs, respectively. For PBMCs, average accuracy and precision at four quality control levels were found to be 93.30%-110.00% and 6.52%-8.25%, respectively. Plasma and intracellular pharmacokinetics of BTG was evaluated by the developed method in rats and a lack of accumulation of BTG in the PBMCs was observed. Pearson correlation coefficient data analysis indicated a moderated correlation between plasma and PBMC concentration of BTG. Therefore, it will be beneficial to include a quantification plan for BTG in its actual therapeutic target site during all its future research and development work. This reported method can be useful for site-specific monitoring of BTG in research laboratories and pharmaceutical industries.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Leucocitos Mononucleares / Espectrometría de Masas en Tándem Límite: Animals Idioma: En Revista: Anal Biochem Año: 2023 Tipo del documento: Article País de afiliación: India Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Leucocitos Mononucleares / Espectrometría de Masas en Tándem Límite: Animals Idioma: En Revista: Anal Biochem Año: 2023 Tipo del documento: Article País de afiliación: India Pais de publicación: Estados Unidos