Your browser doesn't support javascript.
loading
Commutability assessment of human urine certified reference materials for albumin and creatinine on multiple clinical analyzers using different statistical models.
Liu, Hong; Ng, Cheng Yang; Liu, Qinde; Teo, Tang Lin; Loh, Tze Ping; Wong, Moh Sim; Sethi, Sunil Kumar; Tan, Jun Guan; Heng, Ping Ying; Saw, Sharon; Lam, Leslie Choong-Weng; Lee, Joanne Mee-Yin; Khaled, Khairee Bin; Phyu, Hnin Pwint; Ong, Noel Wan Ting.
Afiliación
  • Liu H; Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.
  • Ng CY; Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.
  • Liu Q; Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore. liu_qinde@hsa.gov.sg.
  • Teo TL; Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.
  • Loh TP; Department of Laboratory Medicine, National University Hospital, Singapore, Singapore.
  • Wong MS; Department of Laboratory Medicine, Khoo Teck Puat Hospital, Singapore, Singapore.
  • Sethi SK; Department of Laboratory Medicine, National University Hospital, Singapore, Singapore.
  • Tan JG; Department of Laboratory Medicine, Khoo Teck Puat Hospital, Singapore, Singapore.
  • Heng PY; Department of Laboratory Medicine, Khoo Teck Puat Hospital, Singapore, Singapore.
  • Saw S; Department of Laboratory Medicine, National University Hospital, Singapore, Singapore.
  • Lam LC; Parkway Laboratories, Singapore, Singapore.
  • Lee JM; Parkway Laboratories, Singapore, Singapore.
  • Khaled KB; Department of Laboratory Medicine, Ng Teng Fong General Hospital, Singapore, Singapore.
  • Phyu HP; Department of Laboratory Medicine, Ng Teng Fong General Hospital, Singapore, Singapore.
  • Ong NWT; Department of Laboratory Medicine, Ng Teng Fong General Hospital, Singapore, Singapore.
Anal Bioanal Chem ; 415(5): 787-800, 2023 Feb.
Article en En | MEDLINE | ID: mdl-36562812
Urine albumin concentration and albumin-creatinine ratio are important for the screening of early-stage kidney damage. Commutable urine certified reference materials (CRMs) for albumin and creatinine are necessary for standardization of urine albumin and accurate measurement of albumin-urine ratio. Two urine CRMs for albumin and creatinine with certified values determined using higher-order reference measurement procedures were evaluated for their commutability on five brands/models of clinical analyzers where different reagent kits were used, including Roche Cobas c702, Roche Cobas c311, Siemens Atellica CH, Beckman Coulter AU5800, and Abbott Architect c16000. The commutability study was conducted by measuring at least 26 authentic patient urine samples and the human urine CRMs using both reference measurement procedures and the routine methods. Both the linear regression model suggested by the Clinical and Laboratory Standard Institute (CLSI) guidelines and log-transformed model recommended by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Commutability Working Group were used to evaluate the commutability of the human urine CRMs. The commutability of the human urine CRMs was found to be generally satisfactory on all five clinical analyzers for both albumin and creatinine, suggesting that they are suitable to be used routinely by clinical laboratories as quality control or for method validation of urine albumin and creatinine measurements.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Modelos Estadísticos / Albúminas Tipo de estudio: Guideline / Risk_factors_studies Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article País de afiliación: Singapur Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Modelos Estadísticos / Albúminas Tipo de estudio: Guideline / Risk_factors_studies Límite: Humans Idioma: En Revista: Anal Bioanal Chem Año: 2023 Tipo del documento: Article País de afiliación: Singapur Pais de publicación: Alemania