A Comparison of the bébé VieScope™ and Direct Laryngoscope for Use While Wearing PPE-AGP: A Randomized Crossover Simulation Trial.
Wieczorek, Pawel; Szarpak, Lukasz; Dabrowska, Agata; Pruc, Michal; Navolokina, Alla; Raczynski, Andrzej; Smereka, Jacek.
Afiliación
  • Wieczorek P; Pediatric Intensive Care Unit (PICU), John Paul II Upper Silesian Health Centre in Katowice, 40-752 Katowice, Poland.
  • Szarpak L; Research Unit, Polish Society of Disaster Medicine, 05-806 Warsaw, Poland.
  • Dabrowska A; Research Unit, Maria Sklodowska-Curie Bialystok Oncology Center, 15-027 Bialystok, Poland.
  • Pruc M; Henry JN Taub Department of Emergency Medicine, Baylor College of Medicine Houston, Houston, TX 77030, USA.
  • Navolokina A; Department of Rescue and Disaster Medicine, Poznan University of Medical Sciences, 60-806 Poznan, Poland.
  • Raczynski A; Research Unit, Polish Society of Disaster Medicine, 05-806 Warsaw, Poland.
  • Smereka J; European School of Medicine, International European University, 03187 Kyiv, Ukraine.
Children (Basel) ; 9(11)2022 Nov 18.
Article en En | MEDLINE | ID: mdl-36421223
This study aimed to compare the intubation effectiveness of the bébé Vie Scope™ (VieScope) and direct laryngoscopy for emergency intubation in a pediatric manikin model performed by paramedics with and without personal protective equipment for aerosol generating procedures (PPE-AGP). Participants performed endotracheal intubation using VieScope and standard Macintosh laryngoscope (MAC) in two research scenarios: (1) without PPE-AGP, and (2) with PPE-AGP. Fifty-one paramedics without any previous experience with the VieScope participated in this study. In the PPE-AGP scenario, in the VieScope group, the percentage of successful tracheal intubation on the first attempt was higher compared to the MAC group (94.1 vs. 78.4%, p = 0.031), intubation time was shorter (29.8 vs. 33.9 s, p < 0.001), and percentage of glottic opening (POGO) score was higher 91.0 vs 77.8 (p < 0.001). On the Cormack−Lehane scale, intubation with VieScope intubation was associated with higher scores rated at 1 (64.7 vs. 29.4%) than in the MAC group (p = 0.001). For intubation in the non-PPE scenario, there were no statistically significant differences between VieScope and MAC in relation to above parameters. Summarize, the bébé VieScope™ under PPE-AGP wearing conditions has proven to be a useful device for airway management in children providing better visualization of the larynx, better intubation conditions, and a higher success rate of tracheal intubation on the first attempt and reduced intubation time compared to the standard Macintosh laryngoscope.