Your browser doesn't support javascript.
loading
Gamma counting protocols for the accurate quantification of 225Ac and 213Bi without the need for a secular equilibrium between parent and gamma-emitting daughter.
Castillo Seoane, Dayana; De Saint-Hubert, Marijke; Ahenkorah, Stephen; Saldarriaga Vargas, Clarita; Ooms, Maarten; Struelens, Lara; Koole, Michel.
Afiliación
  • Castillo Seoane D; Unit of Nuclear Medicine and Molecular Imaging, Department of Imaging and Pathology, Katholieke Universiteit Leuven (KUL), Louvain, Belgium. marijke.de.saint-hubert@sckcen.be.
  • De Saint-Hubert M; Research Unit in Dosimetric Applications, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium. marijke.de.saint-hubert@sckcen.be.
  • Ahenkorah S; Research Unit in Dosimetric Applications, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium.
  • Saldarriaga Vargas C; NURA Research Group, Belgian Nuclear Research Center (SCK CEN), Mol, Belgium.
  • Ooms M; Unit of Radiopharmaceutical Research, Department of Pharmaceutical and Pharmacological Sciences, Katholieke Universiteit Leuven (KUL), Louvain, Belgium.
  • Struelens L; Research Unit in Dosimetric Applications, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium.
  • Koole M; Department of Medical Imaging, Laboratory for In Vivo Cellular and Molecular Imaging, Vrije Universiteit Brussel (VUB), Brussels, Belgium.
EJNMMI Radiopharm Chem ; 7(1): 28, 2022 Oct 23.
Article en En | MEDLINE | ID: mdl-36274098
BACKGROUND: Quantification of actinium-225 through gamma counter measurements, when there is no secular equilibrium between actinium-225 and its gamma emitting daughters bismuth-213 and/or francium-221, can provide valuable information regarding the possible relocation of recoiled daughters such that related radiotoxicity effects can be evaluated. This study proposes a multiple time-point protocol using the bismuth-213 photopeak with measurements before secular equilibrium between actinium-225 and bismuth-213, and a single time-point protocol using both the francium-221 and bismuth-213 photopeak while assuming secular equilibrium between actinium-225 and francium-221 but not between bismuth-213 and actinium-225. RESULTS: Good agreement (i.e. 3% accuracy) was obtained when relying on a multiple time-points measurement of bismuth-213 to quantify both actinium-225 and excess of bismuth-213. Following scatter correction, actinium-225 can be accurately quantified using the francium-221 in a single time-point measurement within 3% of accuracy. The analysis performed on the stability data of [225Ac]Ac-DEPA and [225Ac]Ac-DOTA complexes, before secular equilibrium between bismuth-213 and actinium-225 was formed, revealed considerable amounts of unbound bismuth-213 (i.e. more than 90%) after 24 h of the radiolabeling most likely due to the recoiled daughter effect. CONCLUSION: Both protocols were able to accurately estimate 225Ac-activities provided the francium-221 energy window was corrected for the down scatter of the higher-energy gamma-emissions by bismuth-213. This could prove beneficial to study the recoiled daughter effect and redistribution of free bismuth-213 by monitoring the accumulation or clearance of bismuth-213 in different tissues during biodistribution studies or in patient samples during clinical studies. On the other hand, the single gamma counter measurement protocol, although required a 30 min waiting time, is more time and cost efficient and therefore more appropriate for standardized quality control procedures of 225Ac-labeled radiopharmaceuticals.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: EJNMMI Radiopharm Chem Año: 2022 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline Idioma: En Revista: EJNMMI Radiopharm Chem Año: 2022 Tipo del documento: Article País de afiliación: Bélgica Pais de publicación: Reino Unido