Your browser doesn't support javascript.
loading
Long-term outcomes of retrospective case series of middle ear implantation with Vibrant Soundbridge in children with congenital aural atresia.
Cadre, Barbara; Simon, François; Célérier, Charlotte; Coudert, Cyrille; Flament, Jonathan; Loundon, Natalie; Belhous, Kahina; Denoyelle, Françoise.
Afiliación
  • Cadre B; Université Paris Cité, 75006, Paris, France.
  • Simon F; Department of Paediatric Otolaryngology, AP-HP, Hôpital Necker-Enfants Malades, 149 rue de Sèvres, 75015, Paris, France.
  • Célérier C; Université Paris Cité, 75006, Paris, France. fsimon05@gmail.com.
  • Coudert C; Department of Paediatric Otolaryngology, AP-HP, Hôpital Necker-Enfants Malades, 149 rue de Sèvres, 75015, Paris, France. fsimon05@gmail.com.
  • Flament J; Department of Paediatric Otolaryngology, AP-HP, Hôpital Necker-Enfants Malades, 149 rue de Sèvres, 75015, Paris, France.
  • Loundon N; Department of Paediatric Otolaryngology, AP-HP, Hôpital Necker-Enfants Malades, 149 rue de Sèvres, 75015, Paris, France.
  • Belhous K; Audika Hearing Expertise Laboratory, 19, avenue des Gobelins, 75005, Paris, France.
  • Denoyelle F; Department of Paediatric Otolaryngology, AP-HP, Hôpital Necker-Enfants Malades, 149 rue de Sèvres, 75015, Paris, France.
Eur Arch Otorhinolaryngol ; 280(4): 1629-1637, 2023 Apr.
Article en En | MEDLINE | ID: mdl-36098862
PURPOSE: to assess audiological performance in quiet and noise, quality of life and side effects of Vibrant Soundbridge (VSB) in children with congenital aural atresia (CAA). METHODS: A retrospective study including consecutive patients with unilateral or bilateral CAA implanted with VSB from 2009 to 2020 in a tertiary referral centre. RESULTS: 18 patients with CAA and a present stapes were included (3 simultaneous bilateral VSB implants) and 21 ears: 17 VSB were attached to the short incus process, and four to the stapes. Age at implantation ranged from 4.7 to 15.8 years. Average follow-up was 6.5 years (± 3.7 years). In unilateral VSB, air conduction pure tone average (ACPTA) thresholds increased from 75.3 ± 15.2 to 32.6 ± 8.3 dB post-operatively (VSB activated) (n = 15; p < 0.01). The speech reception threshold (SRT) and the word recognition score (WRS) were significantly improved from 81.5 ± 10.4 to 43.9 ± 7.6 dB and 0% to 84.8 ± 8.5% postoperatively (n = 15; p < 0.01). The signal to noise ratio (SNR) was significantly improved from 2.1 ± 2.9 dB VSB inactivated to 0.3 ± 2.7 dB VSB activated (n = 15; p < 0.01). There was no significant difference in performance according to floating mass transducer (FMT) placement. 5/15 children were non-users at last follow-up in unilateral VSB and 0/3 in bilateral. CONCLUSIONS: CAA ears with VSB activated had a significant improvement of ACPTA, WRS, SRT and SNR. A third of patients with unilateral CAA became non-users at last follow-up. The main challenge is to target the indications for the implantation of the VSB to avoid its discontinuation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Calidad de Vida / Prótesis Osicular Tipo de estudio: Observational_studies Aspecto: Patient_preference Límite: Adolescent / Child / Child, preschool / Humans Idioma: En Revista: Eur Arch Otorhinolaryngol Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Calidad de Vida / Prótesis Osicular Tipo de estudio: Observational_studies Aspecto: Patient_preference Límite: Adolescent / Child / Child, preschool / Humans Idioma: En Revista: Eur Arch Otorhinolaryngol Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2023 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Alemania