Your browser doesn't support javascript.
loading
A wideband circularly polarized CPW-fed substrate integrated waveguide based antenna array for ISM band applications.
Ahmad, Sarosh; Cherif, Nabil; Naseer, Salman; Ijaz, Umer; Faouri, Yanal S; Ghaffar, Adnan; Hussein, Mousa.
Afiliación
  • Ahmad S; Department of Electrical Engineering and Technology, Government College University Faisalabad (GCUF), 38000, Faisalabad, Pakistan.
  • Cherif N; Department of Signal Theory and Communications, Universidad Carlos III de Madrid, 28911 Leganés, Madrid, Spain.
  • Naseer S; LSTE Laboratory, Mustapha Stambouli University, Mascara, Algeria.
  • Ijaz U; Department of Information Technology, University of the Punjab Gujranwala Campus, Pakistan.
  • Faouri YS; Department of Electrical Engineering and Technology, Government College University Faisalabad (GCUF), 38000, Faisalabad, Pakistan.
  • Ghaffar A; Electrical Engineering Department, The University of Jordan, Amman, Jordan.
  • Hussein M; Department of Electrical and Electronic Engineering Auckland University of Technology, Auckland, New Zealand.
Heliyon ; 8(8): e10058, 2022 Aug.
Article en En | MEDLINE | ID: mdl-36033273
This article presents a compact size circularly polarized substrate integrated waveguide (SIW) based wideband antenna array that serves industrial, scientific, and medical (ISM) band applications. A coplanar waveguide (CPW) technique is used to ensure the antenna size compactness. The proposed antenna is fabricated on a low-profile Rogers RT6002 substrate with a dielectric constant of 2.94, tanδ of 0.0012 and an approximate height of 0.76mm. The proposed design covers the frequency range from 2.15 GHz to 3.63 GHz (60.4%) while the axial ratio has a 3 dB bandwidth covering from 2.19 GHz to 2.51 GHz (13%) at the operating band of 2.45 GHz. The antenna is miniaturized and has a size of about 46.50 × 29 × 0.76 mm3. The simulation and experimental results are taken into consideration and there is a good promise between them. Hence, the antenna is a suitable applicant to be utilized for the applications in the ISM band.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2022 Tipo del documento: Article País de afiliación: Pakistán Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Heliyon Año: 2022 Tipo del documento: Article País de afiliación: Pakistán Pais de publicación: Reino Unido