Generation of hemipelvis surface geometry based on statistical shape modelling and contralateral mirroring.
Krishna, Praveen; Robinson, Dale L; Bucknill, Andrew; Lee, Peter Vee Sin.
Afiliación
  • Krishna P; Department of Biomedical Engineering, University of Melbourne, Melbourne, VIC, 3010, Australia.
  • Robinson DL; Department of Biomedical Engineering, University of Melbourne, Melbourne, VIC, 3010, Australia.
  • Bucknill A; Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, VIC, Australia.
  • Lee PVS; Department of Surgery, University of Melbourne, Melbourne, VIC, Australia.
Biomech Model Mechanobiol ; 21(4): 1317-1324, 2022 Aug.
Article en En | MEDLINE | ID: mdl-35713823
Personalised fracture plates manufactured using 3D printing offer an improved treatment option for unstable pelvic ring fractures that may not be adequately secured using off-the-shelf components. To design fracture plates that secure the bone fragments in their pre-fracture positions, the fractures must be reduced virtually using medical imaging-based reconstructions, a time-consuming process involving segmentation and repositioning of fragments until surface congruency is achieved. This study compared statistical shape models (SSMs) and contralateral mirroring as automated methods to reconstruct the hemipelvis using varying amounts of bone surface geometry. The training set for the geometries was obtained from pelvis CT scans of 33 females. The root-mean-squared error (RMSE) was quantified across the entire surface of the hemipelvis and within specific regions, and deviations of pelvic landmarks were computed from their positions in the intact hemipelvis. The reconstruction of the entire hemipelvis surfaced based on contralateral mirroring had an RMSE of 1.21 ± 0.29 mm, whereas for SSMs based on the entire hemipelvis surface, the RMSE was 1.11 ± 0.29 mm, a difference that was not significant (p = 0.32). Moreover, all hemipelvis reconstructions based on the full or partial bone geometries had RMSEs and landmark deviations from contralateral mirroring that were significantly lower (p < 0.05) or statistically equivalent to the SSMs. These results indicate that contralateral mirroring tends to be more accurate than SSMs for reconstructing unilateral pelvic fractures. SSMs may still be a viable method for hemipelvis fracture reconstruction in situations where contralateral geometries are not available, such as bilateral pelvic factures, or for highly asymmetric pelvic anatomies.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Huesos Pélvicos / Fracturas Óseas Tipo de estudio: Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Biomech Model Mechanobiol Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2022 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Huesos Pélvicos / Fracturas Óseas Tipo de estudio: Risk_factors_studies Límite: Female / Humans Idioma: En Revista: Biomech Model Mechanobiol Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2022 Tipo del documento: Article País de afiliación: Australia Pais de publicación: Alemania