Your browser doesn't support javascript.
loading
Stabilization of the Distal Radioulnar Joint with or without Triangular Fibrocartilage Complex Tear by an External Wrist Band Brace: A Cadaveric Study.
Shin, Seung-Han; Park, Taeyong; Hong, Eunah; Kwak, Dai-Soon; Chung, Yang-Guk.
Afiliación
  • Shin SH; Department of Orthopedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Korea.
  • Park T; Yonseihun Hospital, Gwangmyeong-si 14236, Korea.
  • Hong E; Department of Anatomy/Catholic Institute for Applied Anatomy, College of Medicine, The Catholic University of Korea, Seoul 06591, Korea.
  • Kwak DS; Department of Anatomy/Catholic Institute for Applied Anatomy, College of Medicine, The Catholic University of Korea, Seoul 06591, Korea.
  • Chung YG; Department of Orthopedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Korea.
Healthcare (Basel) ; 10(5)2022 Apr 30.
Article en En | MEDLINE | ID: mdl-35627965
The purpose of this study was to investigate whether a watch-shaped external wrist band brace improves distal radioulnar joint (DRUJ) stability. Seven fresh cadaveric arms were used. Using a customized testing system, volar and dorsal translation forces were applied to the radius externally while the ulna was fixed. The test was performed with the forearm in neutral, 60° pronated, and 60° supinated positions, once without the brace and once with the brace applied. In each condition, the amount of translation was measured. Then, the triangular fibrocartilage complex (TFCC) was detached from the ulnar styloid process and the fovea ulnaris, and the same tests were performed again. Detachment of the TFCC significantly increased volar and dorsal translations in all forearm rotations compared to the intact condition (p < 0.05), except for the pronated dorsal translation of the radius (p = 0.091). Brace application significantly reduced volar and dorsal translations in all forearm rotations both in intact specimens and in TFCC-detached specimens (p < 0.05), except for pronated volar and dorsal translations in TFCC-detached specimens (p = 0.101 and p = 0.131, respectively). With the brace applied, the TFCC-detached specimens showed no significant difference in volar or dorsal translation in all forearm rotations compared to the intact specimens (p > 0.05). The external wrist band brace improved DRUJ stability in both normal and TFCC-torn wrists and reduced the DRUJ instability caused by TFCC tear to a near-normal level.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Healthcare (Basel) Año: 2022 Tipo del documento: Article Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Healthcare (Basel) Año: 2022 Tipo del documento: Article Pais de publicación: Suiza