Your browser doesn't support javascript.
loading
Inhibiting effect of CO2 on the oxidative combustion thermodynamics of coal.
Ren, Li-Feng; Li, Qing-Wei; Deng, Jun; Yang, Xiao; Ma, Li; Wang, Wei-Feng.
Afiliación
  • Ren LF; Xi'an University of Science and Technology 58, Yanta Mid. Rd Xi'an Shaanxi 710054 PR China lifengrr@126.com liqingwei90@126.com.
  • Li QW; Post-doctoral Research Center of Mining Engineering, Xi'an University of Science and Technology 58, Yanta Mid. Rd Xi'an Shaanxi 710054 PR China.
  • Deng J; Shaanxi Key Laboratory of Prevention and Control of Coal Fire 58, Yanta Mid. Rd Xi'an Shaanxi 710054 PR China.
  • Yang X; Xi'an University of Science and Technology 58, Yanta Mid. Rd Xi'an Shaanxi 710054 PR China lifengrr@126.com liqingwei90@126.com.
  • Ma L; School of Safety Science and Engineering, Xi'an University of Science and Technology 58, Yanta Mid. Rd Xi'an Shaanxi 710054 PR China.
  • Wang WF; Shaanxi Key Laboratory of Prevention and Control of Coal Fire 58, Yanta Mid. Rd Xi'an Shaanxi 710054 PR China.
RSC Adv ; 9(70): 41126-41134, 2019 Dec 09.
Article en En | MEDLINE | ID: mdl-35540081
A thermal analysis experiment was conducted in O2/N2/CO2 and O2/N2 atmospheres (O2 concentrations were 21, 14, 8, and CO2 concentrations were 0, 39, 46, 52) to investigate the thermal behavior of coal oxidation and combustion. Results demonstrated that an elevated CO2 concentration or decreased O2 concentration had a delaying effect on the thermogravimetric analysis and differential scanning calorimetry (DSC) curves; moreover, the characteristic temperatures were substantially augmented. When the O2 concentration was 21 vol%, the total heat released by coals A (highly volatile bituminous coal) and B (anthracite coal) decreased by 5.8% and 4.1%, respectively, after CO2 addition. The comprehensive combustion performance index was also lowered. The DSC curve can be divided into two exothermic peaks, and the ratio of the peak 1 to peak 2 areas decreased with the addition of CO2, which indicated that CO2 inhibited the oxidation of the active functional groups of coal structures. Apparent activation energy in O2/CO2/N2 was less than that in O2/N2.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: RSC Adv Año: 2019 Tipo del documento: Article Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: RSC Adv Año: 2019 Tipo del documento: Article Pais de publicación: Reino Unido