Evaluation of the rapid antigen detection test STANDARD F COVID-19 Ag FIA for diagnosing SARS-CoV-2: experience from an Emergency Department.
García-Fernández, Sergio; Pablo-Marcos, Daniel; de la Fuente, Silvia Velasco; Rodríguez, María José Reina; Gozalo, Mónica; Rodríguez-Lozano, Jesús; Méndez-Legaza, José Manuel; Calvo, Jorge.
Afiliación
  • García-Fernández S; Servicio de Microbiología, Hospital Universitario Marqués de Valdecilla-IDIVAL, Santander, Spain. Electronic address: segarciafe@hotmail.com.
  • Pablo-Marcos D; Servicio de Microbiología, Hospital Universitario Marqués de Valdecilla-IDIVAL, Santander, Spain.
  • de la Fuente SV; Servicio de Microbiología, Hospital Universitario Marqués de Valdecilla-IDIVAL, Santander, Spain.
  • Rodríguez MJR; Servicio de Microbiología, Hospital Universitario Marqués de Valdecilla-IDIVAL, Santander, Spain.
  • Gozalo M; Servicio de Microbiología, Hospital Universitario Marqués de Valdecilla-IDIVAL, Santander, Spain.
  • Rodríguez-Lozano J; Servicio de Microbiología, Hospital Universitario Marqués de Valdecilla-IDIVAL, Santander, Spain.
  • Méndez-Legaza JM; Servicio de Microbiología, Hospital Universitario Marqués de Valdecilla-IDIVAL, Santander, Spain.
  • Calvo J; Servicio de Microbiología, Hospital Universitario Marqués de Valdecilla-IDIVAL, Santander, Spain.
Diagn Microbiol Infect Dis ; 103(2): 115683, 2022 Jun.
Article en En | MEDLINE | ID: mdl-35421760
The purpose of this study was to assess the clinical performance of STANDARD F COVID-19 Ag FIA (SD Biosensor Inc., Gyeonggi-do, Republic of Korea), a rapid antigen detection test (RADT) for diagnosing SARS-CoV-2, in patients attended at the Emergency Department with signs or symptoms compatible with COVID-19 that had started in the last 5 days. The clinical performance of the antigen test was compared with RT-PCR, the reference standard. We included 663 specimens from non-repetitive patients. Clinical sensitivity and specificity were 84.0% (95% CI 76.1-89.7) and 99.6% (95% CI 98.5-99.9), respectively. The positive and negative predictive values were 98.1% (95% CI 92.7-99.7) and 96.4% (95% CI 94.4-97.7), respectively. The kappa index agreement between RT-PCR and the RADT was 0.89 (95% CI 0.84-0.93). We concluded that STANDARD F COVID-19 Ag FIA is an excellent first-line RADT method to diagnose symptomatic patients in the emergency department.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: SARS-CoV-2 / COVID-19 Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Diagn Microbiol Infect Dis Año: 2022 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: SARS-CoV-2 / COVID-19 Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Diagn Microbiol Infect Dis Año: 2022 Tipo del documento: Article Pais de publicación: Estados Unidos