Your browser doesn't support javascript.
loading
Transcatheter aortic valve-in-valve implantation under cerebral protection in a patient with a deteriorated 19-mm rapid-deployment bioprosthetic valve.
Van Praet, Karel M; Nersesian, Gaik; Kukucka, Marian; Heil, Emanuel; Kofler, Markus; Falk, Volkmar; Klein, Christoph; Kempfert, Joerg; Unbehaun, Axel.
Afiliación
  • Van Praet KM; Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
  • Nersesian G; DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Germany.
  • Kukucka M; Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
  • Heil E; Institute for Anesthesiology, German Heart Center Berlin, Berlin, Germany.
  • Kofler M; Institute for Anesthesiology, German Heart Center Berlin, Berlin, Germany.
  • Falk V; Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
  • Klein C; DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Germany.
  • Kempfert J; Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany
  • Unbehaun A; DZHK (German Center for Cardiovascular Research), Partner Site Berlin, Germany.
Article en En | MEDLINE | ID: mdl-35377972
The introduction of transcatheter aortic valve implantation (TAVI) has dramatically improved the treatment of valvular pathologies in high-risk patients. Additionally, transcatheter aortic valve implantation can be successfully applied in patients with deteriorated surgical bioprosthetic valves, representing an attractive alternative to a redo operation. Valve-in-valve transcatheter aortic valve implantations can be especially challenging in patients with a small-diameter prosthesis and patient-prosthesis mismatch. Bioprosthetic valve fracturing or bioprosthetic valve remodeling can be used to increase the valvular opening area and additionally reduce the transvalvular gradients in patients having an aortic valve implant. In this case report, we provide detailed insight and step-by-step guidance for transcatheter aortic valve-in-valve implantation with bioprosthetic valve fracturing/bioprosthetic valve remodeling under cerebral protection in a patient with a deteriorated 19-mm surgically implanted bioprosthesis.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Multimed Man Cardiothorac Surg Año: 2022 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis Valvulares Cardíacas / Implantación de Prótesis de Válvulas Cardíacas Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Multimed Man Cardiothorac Surg Año: 2022 Tipo del documento: Article País de afiliación: Alemania Pais de publicación: Reino Unido