Your browser doesn't support javascript.
loading
Retrograde Intubation Over a Flexible Fiber-Optic Bronchoscope.
Kang, Ramanjot S; Hutnik, Robert; Kant, Ishu; Zlatopolsky, Aaron; Brar, Chamandeep; Oleszak, Slawomir P.
Afiliación
  • Kang RS; Department of Anesthesiology, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York.
  • Hutnik R; Department of Anesthesiology, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York.
  • Kant I; Department of Anesthesiology, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York.
  • Zlatopolsky A; Department of Anesthesiology, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York.
  • Brar C; Department of Anesthesiology, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York.
  • Oleszak SP; Department of Anesthesiology, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York.
Anesth Prog ; 69(1): 42-45, 2022 04 01.
Article en En | MEDLINE | ID: mdl-35377936
Traditional retrograde intubation consists of tracheal intubation performed over a guide wire inserted into the trachea inferior to the vocal cords and then passed transorally or transnasally. This intubation technique is reserved for patients with a difficult airway when other methods such as blind nasal intubation or video laryngoscopy fail. A guide wire passed blindly in a retrograde fashion, however, is not without its own constraints. This case report presents the anesthetic management of a 23-year-old Duchenne muscular dystrophy patient with substantial scarring from a previous tracheostomy stoma and limited mouth opening. The patient underwent a retrograde fiber-optic transnasal intubation without the use of a guide wire for a tracheostomy revision procedure, followed by a second tracheostomy revision and retrograde fiber-optic transoral intubation 7.5 months later. This report demonstrates a novel technique for intubating patients with difficult airways. The use of a flexible fiber-optic bronchoscope for a retrograde intubation mitigates complications that can arise using traditional retrograde intubation over a guide wire and increases the likelihood of successful intubation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Broncoscopía / Broncoscopios Límite: Adult / Humans Idioma: En Revista: Anesth Prog Año: 2022 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Broncoscopía / Broncoscopios Límite: Adult / Humans Idioma: En Revista: Anesth Prog Año: 2022 Tipo del documento: Article Pais de publicación: Estados Unidos